Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Thermoplastic enclosure
• Protection class IP65

 
 
Ordering details
 
Product type descriptionSVE3/xxx-W-115VAC
Article numberSVE3/xxx-W-115VAC
EAN Code
noticeIn the order/inquiry the requested lock number "xxx" must be specified (e.g. SVE3/115/115/115-W-115VAC)!
If no lock number is indicated in the order/inquiry, we will supply a lock number at our discretion.
The user must ensure that lock numbers are not assigned twice in a single plant (factory site)!
The user must ensure that no double key bit numbers are allocated on one site (company site)!
eCl@ss27-27-26-03
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)100.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightSchlüssel-Wahlschalter
StandardsIEC/EN 60947-1, IEC 60947-5-1, EN 1088
Compliance with the Directives (Y/N) Yes
Number of key selector switch3
Active principleelectromechanical
Duty cycleMagnet 100
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Material of the contactsSilver
Housing coatingNone
Enclosure colorBlack / Silver
Color
- Colour of the key grip Silver
- Colour of the key Silver
Weight750
Key numberxxx
Key selector switch positionleft, centered, right
Locking systemIncluded in standard version
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Min. Cable section0,25
- Max. Cable section2.5
Mechanical life100.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Emergency unlocking device (Y/N)No
Manual release (Y/N)Yes
Emergency release (Y/N)No
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+50
Protection classIP65 / IP20 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts4
Number of safety contacts4
Power to unlockYes
Power to lockNo
Rated control voltage115
Power consumption8.5
Rated impulse withstand voltage2.5
Rated insulation voltage250
Thermal test current4 A
Utilisation categoryAC-15: 230 V / 4 A,
DC-13: 24 V / 4 A
Max. fuse rating4 A gG D-fuse To DIN EN 60269-1
noticeNC contacts separately
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor96
- Height of sensor169
- Length of sensor144
 
Included in delivery
 
Key and triangular tool included in delivery (incl. 1 key for emergencies)
 
notice - Operating principle
 
see drawing: Operating principleKey 1-3 in Pos. 1, magnet de-energised: key-operated switch locked, NC contacts closed, key not withdrawable
Key 1-3 in Pos. 1, magnet energised NC contact open: key-operated switch unlocked, NC contacts closed, key not withdrawable
Key 1-3 in Pos. 2, magnet energised NC contact open: key-operated switch unlocked, NC contacts open, key withdrawable

Triangular tool for manual release in Pos. 3: key-operated switch mechanically locked, magnet non-operational, NC contact open