Ordering details |
|
Product type description | SVE2/xxx-24VDC |
Article number | SVE2/xxx-24VDC |
EAN Code |
notice | In the order/inquiry the requested lock number "xxx" must be specified (e.g. SVE2/115/115-24VDC)! If no lock number is indicated in the order/inquiry, we will supply a lock number at our discretion. The user must ensure that lock numbers are not assigned twice in a single plant (factory site)! The user must ensure that no double key bit numbers are allocated on one site (company site)! |
eCl@ss | 27-27-26-03 |
|
Classification |
|
Standards | EN ISO 13849-1 |
B10d Normally-closed contact (NC) | 100.000 |
Mission time | 20 Years |
notice |  |
|
Global Properties |
|
Permanent light | Schlüssel-Wahlschalter |
Standards | IEC/EN 60947-1, IEC 60947-5-1, EN 1088 |
Compliance with the Directives (Y/N)  | Yes |
Number of key selector switch | 2 |
Active principle | electromechanical |
Duty cycle | Magnet 100 |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
- Material of the contacts | Silver |
Housing coating | None |
Enclosure color | Black / Silver |
Color |
- Colour of the key grip | Silver |
- Colour of the key | Silver |
Weight | 750 |
Key number | xxx |
Key selector switch position | left, right |
Locking system | Included in standard version |
|
Mechanical data |
|
Connection type | Screw connection |
Cable section |
- Min. Cable section | 0,25 |
- Max. Cable section | 2.5 |
Mechanical life | 100.000 operations |
notice | All indications about the cable section are including the conductor ferrules. |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | Yes |
Emergency release (Y/N) | No |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | 0 |
- Max. environmental temperature | +50 |
Protection class | IP65 / IP20 to IEC/EN 60529 |
|
Electrical data |
|
Design of control element | Normally open contact (NO), Opener (NC) |
Switching principle | Creep circuit element |
Number of auxiliary contacts | 3 |
Number of safety contacts | 2 |
Power to unlock | Yes |
Power to lock | No |
Rated control voltage | 24 |
Power consumption | 8.5 |
Rated impulse withstand voltage | 2.5 |
Rated insulation voltage | 250 |
Thermal test current | 4 A |
Utilisation category | AC-15: 230 V / 4 A, DC-13: 24 V / 4 A |
Max. fuse rating | 4 A gG D-fuse To DIN EN 60269-1 |
notice | NC contacts in series |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 96 |
- Height of sensor | 169 |
- Length of sensor | 144 |
|
Included in delivery |
|
Key and triangular tool included in delivery (incl. 1 key for emergencies) |
|
notice - Operating principle |
|
see drawing: Operating principle | Key 1-3 in Pos. 1, magnet de-energised: key-operated switch locked, NC contacts closed, key not withdrawable Key 1-3 in Pos. 1, magnet energised NC contact open: key-operated switch unlocked, NC contacts closed, key not withdrawable Key 1-3 in Pos. 2, magnet energised NC contact open: key-operated switch unlocked, NC contacts open, key withdrawable
Triangular tool for manual release in Pos. 3: key-operated switch mechanically locked, magnet non-operational, NC contact open Triangular tool for manual release in Pos.4: magnet operational |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
22.02.2019 -
18:36:13h Kasbase 3.3.0.F.64I |