• Thermoplastic enclosure
• RFID-technology for needs-based protection against tampering
• Misaligned actuation possible
• 27 mm x 108.2 mm x 35 mm
• High repeat accuracy of the switching points
• 2 short-circuit proof PNP safety outputs
• Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
• Individual coding with RFID technology
• Coding level "High" according to ISO 14119
• 1 x connector socket M12, 8-pole
• Actuation from side
• Max. 31 sensors can be wired in series.
• serial diagnostic output

 
 
Ordering details
 
Product type descriptionRSS 36-I1-SD-R-ST
Article number101218830
EAN Code4030661416366
eCl@ss27-27-24-01
 
Approval
 
Approval TÜV
USA/CAN
ECOLAB
EAC
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3, EN 62061
PLbis e
Control categorybis 4
PFH2.7 x 10−10/h
SIL3
Mission time20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightRSS 36
StandardsIEC 60947-5-3
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
FunctionSensor for series wiring
Series-wiringup to 31 components
Length of the sensor chainmax. 30 m
MountingFor the assembly of the sensors as well as for flat mounted actuators 25 mm screw length is usually sufficient. The 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing disks are used.
Active principleRFID
CodingIndividual coding
Coding levels according to ISO 14119High
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Material of the active surfacePlastic, glass-fibre reinforced thermoplastic
Housing construction formBlock
Weight
Input for enabling pushbutton, suitable for automatic start (Y/N)No
Input for reset pushbutton, with edge monitoring (Y/N)No
Diagnostic output (Y/N)Yes
Reaction time≤ 100
Duration of risk≤ 200
Time to readiness≤ 5 s
Cascadable (Y/N)Yes
Recommended actuatorRST 36-1, RST 36-1-R
 
Mechanical data
 
Design of electrical connectionConnector M12, 8-pole
mechanical installation conditionsnot flush
Actuating planesActuation from side
Active arealateral
Switch distance12
Ensured switch distance ON10
Ensured switch distance OFF20
hysteresismax. 2 mm
Repeat accuracy R R< 0,5 mm
noticeAxial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm.
see drawing: Operating principle

minimum distance 100 mm in case of approach from side
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Latching (Y/N)Yes
Latching force18
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Temperature resistance cable
- min. Temperature resistance−30 in position of rest, −10 in Movement
- max. Temperature resistance+105
Protection classIP65, IP67, IP69 to IEC/EN 60529
Protection ratingIII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Overvoltage categoryIII
- Degree of pollution3
 
Electromagnetic compatibility (EMC)
 
EMC ratingto IEC 60947-3
Interfering radiationto IEC 61000-6-4
 
Electrical data
 
Cross circuit/short circuit recognition possible (Y/N)Yes
Voltage typeDC
Switch frequency1
Rated insulation voltage Ui32 VDC
Rated operating voltage Ue (stabilised PELV)
- Min. Rated operating voltage20.4 VDC
- Max. Rated operating voltage26.4 VDC
Operating current Ie0,6 A
No-load current I00,1 A
Required rated short-circuit current100 A
noticeThe cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
Rated operating voltage Ue24 VDC −15% / +10%
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of secure semi-conductor outputs2
Max. output current at secured output0,25 A
Rated operating voltagemin. (Ue − 1 V)
Residual current Ir≤ 0,5 mA
Operating current Iemax. 0,25 A
- Ambient temperature: −25 °C … +70 °C≤ 0,1 A
Minimum operating current Im0,5 mA
- Ambient temperature: −25 °C … +65 °C≤ 0,25 A
Utilisation categoryDC-12: 24 V / 0,25 A
DC-13: 24 V / 0,25 A
Voltage drop Ud< 1 V
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)Yes
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of semi-conductor outputs with signaling function1
Rated operating voltageUe < 2 V
Operating current0,05 A
Utilisation categoryDC-12: 24 V / 0,05 A
DC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnostics50
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s3
green LEDSupply voltage
red LEDError
yellow LEDswitching condition
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor106.3
- Height of sensor25
- Length of sensor22
 
Pin assignment
 
1 - A1 UeBrown
2 - X1 Safety input 1White
3 - A2 GNDBlue
4 - Y1 Safety output 1Black
5 - OUT Diagnostic output OUTGrey
6 - X2 Safety input 2violet
7 - Y2 Safety output 2red
8 - IN without functionPink
 
notice
 
Requirements for the safety monitoring module2-channel safety input, suitable for p-type sensors with NO function. The safety monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0,25 ms. The safety monitoring module does not need to have a cross-wire short monitoring function.
noticeCoding procedure: during the individual coding, a RST actuator is taught through a simple routine during start-up, so that any tampering by means of a spare or substitute actuator is permanently excluded.
 
Included in delivery
 
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 24.06.2019 - 01:38:51h Kasbase 3.3.0.F.64I