Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Detects standstill using 2 impulse sensor(s)
• 1 safety contact
• 2 Signalling outputs

 
 
Ordering details
 
Product type descriptionFWS 2106A
Article numberFWS 2106A
EAN Code
eCl@ss27-37-19-01
 
Approval
 
Approval BG
USA/CAN
EAC
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLup d
Control categoryup 3
PFH value1.0 x 10-7/h
SILup 2
Mission time20 Years
 
Global Properties
 
Permanent lightFWS 2106
StandardsIEC/EN 60204-1, EN ISO 13849-1, BG-GS-ET-20
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-3, BG-GS-ET-14
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, ventilated
- Material of the contactsAg-Ni + Au
Weight
Start input (Y/N)No
Feedback circuit (Y/N)Yes
Reset after disconnection of supply voltage (Y/N)No
Automatic reset function (Y/N)No
Reset with edge detection (Y/N)Yes
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Min. Cable section0,2
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)No
Mechanical life50.000.000 operations
Electrical lifetime100.000 operations for 230 VAC, 6 A (cos φ = 1)
hysteresis10 % of standstill frequency
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm
Standstill frequencyInputs X2 / X4: 1 / 2
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+70
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4.8 kV
- Overvoltage categoryIII To VDE 0110
- Degree of pollution2 To VDE 0110
 
Electromagnetic compatibility (EMC)
 
EMC rating10 V/m
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls20.4
- Max. rated DC voltage for controls253
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz20.4
- Max. rated AC voltage for controls, 50 Hz253
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz20.4
- Max. rated AC voltage for controls, 60 Hz253
Contact resistancemax. 100 mΩ
Power consumption< 5
Type of actuationAC/DC
Rated operating voltage Ue24 … 230 VAC/DC
Operating current Ie0,4 A
Electronic protection (Y/N)No
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)No
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)No
Input frequency4000
min. pulse duration125
Input resistanceapprox. 4000 Ω at GND
Input signal "1"10 … 30 VDC
Input signal "0"0 … 2 VDC
Cable length100 m with 0,75 mm² (for Rated voltage)
 
Outputs
 
Stop category0
Number of safety contacts1
Number of auxiliary contacts0
Number of signalling outputs2
Switching capacity
- Switching capacity of the safety contactsmin. 10 mA, max. 6 A
- Switching capacity of the signaling/diagnostic outputsY1, Y2: max. 100 mA
Fuse rating
- Protection of the safety contacts6 A gG D-fuse
- Fuse rating for the signaling/diagnostic outputsshort-circuit proof
Signalling outputY1: Authorized operation, safety contacts on;
Y2: Error, high signal
Utilisation category To EN 60947-5-1AC-15: 230 V / 3 A
DC-13: 24 V / 2 A
Number of undelayed semi-conductor outputs with signaling function2
Number of undelayed outputs with signaling function (with contact)0
Number of delayed semi-conductor outputs with signaling function.0
Number of delayed outputs with signalling function (with contact).0
Number of secure undelayed semi-conductor outputs with signaling function0
Number of secure, undelayed outputs with signaling function, with contact.0
Number of secure, delayed semi-conductor outputs with signaling function0
Number of secure, delayed outputs with signaling function (with contact).0
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s1
 
Integral system diagnosis $missingShortName$
 
Integral system diagnosis ISD
- The following faults are registered by the safety monitoring modules and indicated by ISD
- Interruption of the connections to the inductive proximity switches
- Failure of the safety relay to pull-in or drop-out
- Fault on the input circuits or the relay control circuits of the safety monitoring module
- Failure of the proximity switches
- Failure of one channel being evaluated
 
Miscellaneous data
 
Applications safe standstill monitoring
 
Dimensions
 
Dimensions
- Width45 mm
- Height100 mm
- Depth121 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
To monitor one guard door at plants with dangerous run-on movements up to PL d and Category 3
Standstill monitoring for unlocking solenoid interlocks
The solenoid interlock can be opened, when the fail-safe standstill monitor has detected the end of the run-on movement by means of two inductive proximity switches. When the button (E) is actuated, the coil of the solenoid interlock is energised.
If only one inductive proximity switch is connected to the standstill monitor, the standstill frequencies must be identical and inputs X2 and X4 must be bridged.
For suitable IFL range p-type inductive proximity switches, refer to "Schmersal Catalogue Automatisierungstechnik".
The wiring diagram is shown with guard doors closed and in de-energised condition.
The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 16.06.2019 - 01:22:31h Kasbase 3.3.0.F.64I