Ordering details |
|
Product type description | EX-AZM 170-02ZK-24VAC/DC-3G/D - Ordering suffix |
Article number | EX-AZM 170-02ZK-24VAC/DC-3G/D |
EAN Code |
eCl@ss | 27-27-26-03 |
|
Approval |
|
Approval | ATEX |
|
Classification |
|
Standards | EN ISO 13849-1 |
B10d Normally-closed contact (NC) | 2.000.000 |
Mission time | 20 Years |
notice |  |
|
Global Properties |
|
Permanent light | EX-AZM 170 |
Standards | EN 60079-0, EN 60079-15, EN 60079-31, EN 60947-5-1, BG-GS-ET-19 |
Compliance with the Directives (Y/N)  | Yes |
Duty cycle ED | Magnet 100 % |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
- Material of the contacts | Silver |
Housing coating | None |
Weight |
|
Mechanical data |
|
Design of electrical connection | IDC method of termination |
Cable cross-section of the cable glands |
- Min. Cable cross-section of the cable glands | Ø 6.5 |
- Max. Cable cross-section of the cable glands | Ø 12 |
Cable section |
- Min. Cable section | 1 x 0,75, flexible |
- Max. Cable section | 1 x 1, flexible |
Mechanical life | > 1.000.000 operations |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | Yes |
- bottom |
Emergency release (Y/N) | No |
Latching force | 5 |
Positive break force | 17 |
positive break travel | 11 |
Clamping force F | 1000 N |
Impact energy | 1 J |
Max. Actuating speed | 1 |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −15 |
- Max. environmental temperature | +45 |
Protection class | IP67 to IEC/EN 60529 |
|
Electrical data |
|
Design of control element | Opener (NC) |
Switching principle | Creep circuit element |
Number of auxiliary contacts | 0 |
Number of safety contacts | 2 |
Power to unlock | Yes |
Power to lock | No |
Rated control voltage Us | 24 VAC/DC |
Power consumption | max. 10 W |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Thermal test current Ithe | 2 A |
Utilisation category | AC-15: 230 V / 2 A, DC-13: 24 V / 2 A |
Max. fuse rating | 6 A gG D-fuse |
|
ATEX |
|
EX-marking | EX II 3D Ex tc IIIC T80°C Dc X EX II 3G Ex nC IIB T5 Gc X |
Explosion protection categories for gases | 3G |
Explosion protection Zones for gases | 2 |
Explosion protected category for dusts | 3D |
Explosion protection Zones for dusts | 22 |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 90 |
- Height of sensor | 84 |
- Length of sensor | 30 |
|
notice |
|
This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules |
Individual coding available on request |
Manual release |
- For manual release using M5 triangular key, available as accessory |
|
Included in delivery |
|
Actuators must be ordered separately. |
Including Ex-certified screwed cable gland and screw plug |
|
Keywords |
|
Keywords | Ex, EEx, ATEX, Ex AZM170, Ex AZM170, AZM 170 Ex, AZM170ex, AZM170ex, ATEX AZM170 |
|
Diagram |
|

Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact |
|
Switch travel diagram |
|

Notes Switch travel diagram
Contact closed
Contact open
Setting range
Break point
Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
|
|
Ordering suffix |
|
The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: EX-AZM 170-02ZK-24VAC/DC-3G/D-1637
|
...-1637 | 0,3 µm gold-plated contacts
|
|
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
19.02.2019 -
20:33:05h Kasbase 3.3.0.F.64I |