Ordering details |
|
Product type description | EX-BNS 33-12ZG-2187-3G/D |
Article number | EX BNS 33-12ZG-2187-3G/D |
EAN Code |
eCl@ss | 27-27-24-02 |
|
Approval |
|
Approval | ATEX |
|
Classification |
|
Standards | EN ISO 13849-1 |
B10d Normally-closed contact/Normally open contact (NC/NO) | 25.000.000 |
- notice | at max. 20% contact load |
Mission time | 20 Years |
notice |  |
|
Global Properties |
|
Permanent light | EX-BNS 33 |
Standards | EN 60079-0, EN 60079-15, EN 60079-31, IEC 60947-5-3, EN 13463-1, EN 13463-5, BG-GS-ET-14 |
Compliance with the Directives (Y/N)  | Yes |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
- Material of the cable mantle | PVC |
Housing construction form | Block |
Weight |
Monitoring function of downstream devices (Y/N) | No |
Prerequisite evaluation unit | Yes |
Recommended safety-monitoring module |
Recommended actuator | EX-BPS 33-3G/D |
|
Mechanical data |
|
Design of electrical connection | Cable |
Cable length | 1 |
Conductors | 6 x 0,25 |
AWG-Number | 23 |
mechanical installation conditions | not flush |
Active area | Side |
Ensured switch distance ON Sao | 5 mm |
Ensured switch distance OFF Sar | 15 mm |
Repeat accuracy R R | ≤ 0,1 x Sao |
Type of actuation | Magnet |
Direction of motion | head-on with regard to the active surface |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 55 HZ, Amplitude 1 mm |
Impact energy | max. 2 Nm |
|
Ambient conditions |
|
Ambient temperature |
Storage and transport temperature |
Protection class | IP67 |
|
Electrical data |
|
Integrated Safety monitoring module available (Y/N) | No |
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Voltage type | VDC |
Switch frequency | max. 5 HZ |
Switching voltage | max. 24 VDC |
Switching current | max. 10 mA |
Switching capacity | max. 240 mW |
|
Outputs |
|
Design of control output | Other, Reed contakts |
Number of shutters | 1 |
Number of openers | 2 |
|
Electrical data - Safety outputs |
|
Number of secure semi-conductor outputs | 0 |
Number of secure outputs with contact | 0 |
|
Electrical data - Diagnostic output |
|
Number of semi-conductor outputs with signaling function | 0 |
Number of outputs with signaling function that already have a contact | 0 |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
- The LED is illuminated when the guard door is open. |
|
ATEX |
|
EX-marking | EX II 3D Ex tc IIIC T80°C Dc X EX II 3G Ex nC IIC T6 Gc X |
Explosion protection categories for gases | 3G |
Explosion protection Zones for gases | 2 |
Explosion protected category for dusts | 3D |
Explosion protection Zones for dusts | 22 |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 88 |
- Height of sensor | 25 |
- Length of sensor | 13 |
|
notice |
|
Contact symbols shown for the closed condition of the guard device. |
The contact configuration for versions with or without LED is identical. |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
Keywords |
|
Keywords | Ex, EEx, ATEX, Ex BNS33, Ex BNS 33, BNS33 Ex, BNS33ex, BNS 33ex, ATEX BNS 33 |
|
Diagram |
|

Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
22.02.2019 -
04:26:16h Kasbase 3.3.0.F.64I |