Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Thermoplastic enclosure
• slender shock-proof enclosure
• to be fitted to commercial-off-the-shelf aluminium profiles
• to be installed at an ergonomic favourable position
• large range of Illuminated pushbuttons, Selector switches, LED indicator lights, Key-operated selector switches and Emergency-Stop buttons
• Emergency stop, on/off and reset functions available
• The position of the pushbuttons on the control panel can be freely selected.
• Field labelling with separate plastic cover
• Freely installable button caps for an optimal adaptation to the plants

 
 
Ordering details
 
Product type descriptionBDF200
Article numberBDF200
noticesee ordering code
eCl@ss
 
Approval
 
Approval USA/CAN
EAC
 
Global Properties
 
Permanent lightBDF200
Climatic stressEN 60068-2-3
Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
 
Mechanical data
 
Cable entry1x M20
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+65
Overvoltage categoryIII
Degree of pollution3

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.