Ordering details |
|
Product type description | AZ 200SK-T-SD2P |
Article number | AZ 200SK-T-SD2P |
EAN Code |
eCl@ss | 27-27-26-02 |
|
Approval |
|
Approval | USA/CAN
TÜV
EAC |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508 |
PL | e |
Control category | 4 |
PFH | 4.0 x 10-9/h |
SIL | 3 |
Mission time TM | 20 Years |
Classification | PDF-M |
|
Global Properties |
|
Permanent light | AZ 200 |
Standards | IEC 60947-5-3, IEC 61508, EN ISO 13849-1, EN ISO 13849-1 |
Compliance with the Directives (Y/N)  | Yes |
Suitable for safety functions (Y/N) | Yes |
Series-wiring | up to 31 components |
Length of the sensor chain | max. 200 m |
Active principle | Non-contact |
Duty cycle ED | 100 % |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
Housing coating | None |
Weight |
Actuator monitored (Y/N) | Yes |
Idle assignable pushbutton and LED (Y/N) | No |
Reaction time | ≤ 60 |
Duration of risk | > 120 |
Time to readiness | 4000 |
Recommended actuator | AZ/AZM 200-B1 |
|
Mechanical data |
|
Design of electrical connection | Screw connection |
notice | All indications about the cable section are including the conductor ferrules. |
Cable section |
- Min. Cable section | 0,25 |
- Max. Cable section | 1.5 |
AWG-Number | 30.1 - 14.7 |
Mechanical life | ≥ 1.000.000 operations |
Switch distance Sn | 6.5 mm |
Ensured switch distance ON Sao | 4 mm |
Ensured switch distance OFF Sar | 30 mm |
hysteresis | max. 1.5 |
Repeat accuracy R R | < 0,5 mm |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 55 HZ, Amplitude 1 mm |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | No |
Emergency release (Y/N) | No |
Latching force | 30 |
Max. Actuating speed | ≤ 0,2 |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +70 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Relative humidity | 30… 95 |
- non-condensing |
Protection class | IP67 to IEC/EN 60529 |
Protection rating | II |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp | 0,8 kV |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electrical data |
|
Number of auxiliary contacts | 0 |
Number of safety contacts | 2 |
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Switch frequency | 1 |
Rated insulation voltage Ui | 32 VDC |
Rated operating voltage Ue |
- Min. Rated operating voltage | 20.4 VDC |
- Max. Rated operating voltage | 26.4 VDC |
Operating current Ie | 0,7 A |
Utilisation category | DC-13 |
No-load current I0 | 0,1 A |
Device insulation | ≤ 4 A if used in accordance with UL 508 |
|
Electrical data - Safety inputs |
|
Safety inputs | X1 and X2 |
Rated operating voltage Ue | - 3 V … 5 V (Low) 15 V … 30 V (High) |
Operating current Ie | > 2 mA / 24 V |
|
Electrical data - Safety outputs |
|
Safety outputs | Y1 and Y2 |
Fuse rating | short-circuit proof |
Design of control output | p-type |
Rated operating voltage | 0 V … 4 V under Ue |
Residual current Ir | ≤ 0,5 mA |
Operating current Ie | 0,25 A |
Utilisation category | DC-13: 24 V / 0,25 A |
|
Electrical data - Diagnostic output |
|
Serial diagnostics (Y/N) | Yes |
Fuse rating | short-circuit proof |
Design of control output | p-type |
Operating current Ie | 0,05 A |
Utilisation category | DC-13: 24 V / 0,05 A |
Wiring capacitance for serial diagnostics | max. 50 nF |
diagnostic signals | to SD-interface |
Operating principle of the diagnostic output | The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
notice | The diagnostic output is not a safety-relevant output! |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
LED switching conditions display |
- Supply voltage | green LED |
- switching condition | yellow LED |
- Error functional defect | red LED |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 40 |
- Height of sensor | 220 |
- Length of sensor | 50 |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
21.02.2019 -
23:18:30h Kasbase 3.3.0.F.64I |