Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Safe active AS-i distributor
• Can be used for CSS and RSS sensors, as well as for MZM 100, AZM 201, AZM 300
• Connections for profile cable AS-i & AUX
• With 2 fail-safe inputs for OSSDs and one digital output that is not fail-safe
• M12, 8-pole connecting cable 1 m
• Protection type IP67

 
 
Ordering details
 
Product type descriptionBWU3635
Article number103016678
EAN Code
eCl@ss27-27-24-02
 
Approval
 
Approval
 
Classification
 
StandardsEN ISO 13849-1, EN 62061
PLe
Control category4
PFH value5.18 x 10−9 / h
PFD value6.19 x 10−7
SILSuitable for SIL 3 applications
Mission time20 Years
 
Global Properties
 
Permanent lightBWU3635
StandardsEN 62026-2, EN ISO 13849-1, EN 62061
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Materials
- Material of the housingsPlastic
- Material of the cablePUR
Weight100
Response time< 11
 
Mechanical data
 
Design of electrical connectionCable connector M12, 8-pole, A-coded
Cable length1.0
restistance to shock15 / 11
Resistance to vibration10 … 55 HZ, Amplitude 0,5 mm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−20
- Max. environmental temperature+60
Storage and transport temperature
- Min. Storage and transport temperature−30
- Max. Storage and transport temperature+85
Protection classIP67
 
Electrical data - AS interface
 
AS-i Supply voltage21.6 … 31.6 VDC
AS-i operating current≤ 60
AS-i SpecificationSafety Slave
- versionV2.1
- ProfileS-7BF1
AS-i Inputs
- Channel 1Data bits DI 0/DI 1= dynamic code transmission
- Channel 2Data bits DI 2/DI 3= dynamic code transmission
AS-i Outputs
- DO 0Digital output, Solenoid control
- DO 1 ... DO 3not used
AS-i Parameter bits
- P0Control system watchdog
- P1Diagnostics signal safety switchgear (Inverted)
- P2 ... P3not used
- Min. supply voltage
- Max. supply voltage
AS-i input module address0
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device
notice-Parameter requestSet the parameter outputs to "1111" (0xF)
Aux Supply voltage24 VDC
Aux Operating current750
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED status indication
(1) green/red LED (AS-i duo LED)Supply voltage / Communication error / slave address = 0 / periphery error detected
(2) green LEDAUX-Power available
(3) yellow LEDS1 = Status Safety input 1
(4) yellow LEDS2 = Status Safety input 2
(5) yellow LEDI1 = Status Input I1
(6) yellow LEDo1 = Status Output o1
 
Dimensions
 
Dimensions
- Width60
- Height45
- Depth19

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.