Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Thermoplastic enclosure
• RFID-technology for needs-based protection against tampering
• Max. length of the sensor chain 200 m
• Self-monitoring series-wiring of 31 sensors
• 3 LEDs to show operating conditions
• Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
• Suitable for hinged and sliding guards
• Intelligent diagnosis

 
 
Ordering details
 
Product type descriptionAZ201ST2-T-1P2P
Article number103015816
EAN Code4030661504308
eCl@ss27-27-26-02
 
Approval
 
Approval

 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLup e
Control categoryup 4
PFH1.9 x 10-9/
PFD value1.6 x 10−4
SIL3
Mission time20 Years
 
Global Properties
 
Permanent lightAZ201
StandardsIEC 60947-5-1, IEC 60947-5-3, ISO 14119, ISO 13849-1, IEC 61508, IEC 62061
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Protection ratingIII
Series-wiringup to 31 components
Length of the sensor chain200
Active principleRFID, 125 kHz
Coding levels according to ISO 14119High
CodingIndividual coding, multiple teaching
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight550 g
Idle assignable pushbutton and LED (Y/N)No
Response time
- Actuator≤ 100 ms
- Inputs≤ 0,5 ms
Duration of risk< 200 ms
Time to readiness< 4000 ms
Recommended actuatorAZ/AZM201-B1, AZ/AZM201-B30
 
Mechanical data
 
Design of electrical connectionConnector M12, 8-pole
Cable section
- Min. Cable section-
- Max. Cable section-
AWG-Number-
Mechanical life≥ 1.000.000 operations
notice-
restistance to shock30 / 11
Resistance to vibration10 … 150 HZ, Amplitude 0,35 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)No
Emergency release (Y/N)No
Latching force30
Max. Actuating speed≤ 0,2
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30… 95
- non-condensing
Protection classIP66, IP67 to IEC/EN 60529
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Supply voltage
- Min. supply voltage20.4 VDC
- Max. supply voltage26.4 VDC
Switch frequency1 HZ
Rated insulation voltage32 VDC
Operating current0,7 A
Utilisation categoryDC-13
No-load current0,1 A
Device insulation≤ 4 A if used in accordance with UL 508
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
Rated operating voltage- 3 … 5 (Low)
15 … 30 (High)
Operating currenttypically 2 at 24
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof, p-type
Rated operating voltage0 … 4 under
Residual current≤ 0,5
Operating currenteach 0,25 A
Utilisation categoryDC-13
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)No
Fuse ratingp-type, short-circuit proof
Operating current0,05 A
Utilisation categoryDC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnostics-
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltagegreen LED
- switching conditionyellow LED
- Error functional defectred LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor220
- Length of sensor50
 
Pin assignment
 
1A1 Supply voltage
2X1 Safety input 1
3A2 GND
4Y1 Safety output 1
5OUT Diagnostic output
6X2 Safety input 2
7Y2 Safety output 2
8-
 
Included in delivery
 
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 26.05.2019 - 07:31:26h Kasbase 3.3.0.F.64I