Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Control panels  ->  BDF200-SD/FB  ->  BDF200-FB-NH-LT-LT-LT-2875
 Add Product to the basket. 
BDF200-FB-NH-LT-LT-LT-2875
• Integrated FB interface for command and signaling devices
• Device version for connection to a Safety-Field-Box SFB
• E-STOP with electronic OSSDs
• Thermoplastic enclosure
• slender shock-proof enclosure
• to be fitted to commercial-off-the-shelf aluminum profiles
• Connector M12, 8-pole

 
 
Ordering details
 
Product type descriptionBDF200-FB-NH-LT-LT-LT-2875
Article number103015447
notice
eCl@ss
 
Approval
 
Approval
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLup e
Control categoryup 4
PFH value2.89 x 10−10 /h
- noticeup to max. 5.000 switching cycles/year
SILup 3
Mission time20 Years
 
Global Properties
 
Product nameBDF200-FB
StandardsIEC 60947-5-1, IEC 60947-5-5, ISO 13850, ISO 13849-1, IEC 61508
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Climatic stressto EN 60068-2-30
Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Weight340 g
Positions used
- Position 1NH, Emergency stop
- Position 2LT-2875, Illuminated pushbutton
- Position 3LT-2875, Illuminated pushbutton
- Position 4LT-2875, Illuminated pushbutton
Response time< 50 ms
Duration of risk≤ 100 ms
 
Mechanical data
 
terminationconnector plug M12, 8-pole, A-coded
Mechanical life
- Emergency-Stop button100.000 operations
- Command devices1.000.000 operations
restistance to shock30 g / 11 ms
Resistance to vibration10 … 150 HZ, Amplitude 0,35 mm / 5 g
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+65 °C
Storage and transport temperature
- Min. Storage and transport temperature−25 °C
- Max. Storage and transport temperature+85 °C
Protection classIP64
Protection ratingIII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8 kV
- Rated insulation voltage32 VDC
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Rated operating voltage24 VDC −15 % / +10 %
(PELV to IEC 60204-1)
Operating current0,6 A
No-load current35 mA
Required rated short-circuit current100 A
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
Rated operating voltage24 VDC −15 % / +10 %
Switching thresholds−3 V … 5 V (low)
15 V … 30 V (High)
Operating current5 mA / 24 V
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Design of control outputshort-circuit proof, p-type
Rated operating voltage24 VDC −15 % / +10 %
Residual current≤ 0,5 mA
Operating current0,25 A
Minimum operating current
Utilisation categoryDC-12: Ue/Ie: 24 VDC / 0,25 A,
DC-13: U
e/Ie: 24 VDC / 0,25 A
Voltage drop< 1 V
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)Yes
Design of control outputshort-circuit proof, p-type
Rated operating voltage24 VDC −15 % / +10 %
Operating current0,15 A
Wiring capacitancemax. 50 nF
 
LED switching conditions display
 
LED switching conditions display (Y/N)No
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions
- Width40 mm
- Height69 mm
- Depth233.5 … 252.5 mm (without and with Indicator lamp)

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 16.06.2019 - 01:25:34h Kasbase 3.3.0.F.64I