Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Solenoid interlock  ->  AZM400  ->  AZM400Z-ST2-I2-2P2P-BOW-E
 Add Product to the basket. 
AZM400Z-ST2-I2-2P2P-BOW-E
• Bistable, motor-driven system
• Clamping force 10.000
• Release possible against lateral forces up to 300 N
• PL e / cat. 4 / SIL 3 for interlocking and guard locking function
• Two-channel input signal of the guard locking function
• Operation on P/P- and P/N-switching outputs
• High tolerance to door misalignment
• Universal coding with RFID technology
• 2 Connector M12, 8- and 5-poles
• Guard locking monitored
• 2 Diagnostic outputs
• With securing holes for Bowden cable assembly
• Electric manual release with auxiliary voltage
• Repeated individual coding with RFID technology

 
 
Ordering details
 
Product type descriptionAZM400Z-ST2-I2-2P2P-BOW-E
Article number103015313
EAN Code4030661503981
eCl@ss27-27-26-03
 
Approval
 
Approval

 
Classification
 
Interlocking function:
StandardsISO 13849-1, IEC 61508
PLup e
Control categoryup 4
PFH value1.0 x 10−9 / h
PFD value9.0 x 10−5
SILup 3
Mission time20 Years
Guard locking function:
StandardsISO 13849-1, IEC 61508
PLup e
Control categoryup 4
PFH value1.8 x 10−9/h
PFD value1.6 x 10−4
SILup 3
Mission time20 Years
 
Global Properties
 
Permanent lightAZM400
StandardsIEC 60947-5-1, ISO 14119, ISO 13849-1, IEC 61508
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Active principleMagnetic field / RFID
CodingIndividual coding, multiple teaching
Coding levels according to ISO 14119High
Material of the housingslight alloy die-casting
Housing coatingNone
Weight730
Guard locking monitored (Y/N)Yes
Idle assignable pushbutton and LED (Y/N)No
Reaction time≤ 100
Time to readiness≤ 1.5 s
Recommended actuatorAZM400-B1
 
Mechanical data
 
Design of electrical connection2 Connector M12, 8- and 5-poles
Interlocking principlebistable
Mechanical life≥ 1.000.000 operations
- which have a lateral force Fquer = 100100.000 operations
Switch distance
- Allowable distance actuator / device incl. angular misalignment1 … 7
- Minimum distance devices30
restistance to shock30 / 11
Resistance to vibration10 … 150 HZ, Amplitude 0,35 mm
Emergency unlocking device (Y/N)Yes
Manual release (Y/N)No
Electronic manual release available (Y/N)Yes
Clamping force10.000
Max. lateral force at bolt return (against locked door)300
- Notice: does not apply to emergency exit, Bowden cable and manual release
fixing screws2 x M6 (10.9)
Tightening torque for fixing screws8
Actuator and interlock misalignment2
With securing holes for Bowden cable assembly (Y/N)Yes
Tightening torque of the fixing screws Bowden cable1.2 Nm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−40
- Max. Storage and transport temperature+85
Protection classIP66, IP67 to IEC/EN 60529
Protection ratingIII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Supply voltage (stabilised PELV)24 −15 / +10
Switch frequency0,3
Operating current0,1 A
- During the displacement of the bolt0,6 A
Rated insulation voltage32 VDC
Required rated short-circuit current100 A
Device insulation2 A
Auxiliary voltage (uninterruptible power supply)24 −15 / +10
Min. open / close cycle (Motor)3
- with continuous operation min. average cycle time20
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Design of control outputshort-circuit proof, p-type
Rated operating voltage24
Residual current≤ 0,5
Operating current0,25 A
Utilisation categoryDC-12, DC-13
Voltage drop≤ 2
Test impulse width≤ 0,4
Test frequency1
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)No
Design of control outputshort-circuit proof, p-type
Number of diagnostic signals2
Rated operating voltage24
Operating current0,05 A
Voltage drop≤ 2
Utilisation categoryDC-12, DC-13
Operating principle of the diagnostic outputThe short-circuit-proof diagnostic outputs OUT1 and OUT2 can be used for central displaying or control tasks, e.g. in a PLC.
noticeThe diagnostic output are not safety relevant outputs!
 
Electrical data - Control inputs
 
Control inputs to unlockE1 and E2, p-type; E3, n-type
Switching thresholds−3 … 5 (Low)
15 … 30 (High)
Operating current per input> 10 … < 15 / 24
Permissible residual drive current1.5
Allowable discrepancy time input≤ 10
Acceptable test impulse on the input signal< 5
- with a test impulse distance of≥ 40
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltagegreen LED
- switching conditionyellow LED
- Error functional defectred LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor77.8
- Height of sensor166.7
- Length of sensor65.3
 
Pin assignment
 
1OUT2 Diagnostic output 2
2E1 Control input 1
3- (not used)
4Y1 Safety output 1
5OUT1 Diagnostic output 1
6E3 Control input 3
7Y2 Safety output 2
8E2 Control input 2
1 (ST2)A1 Supply voltage
2 (ST2)H2 GND
3 (ST2)A2 GND
4 (ST2)H1 Auxiliary voltage
5 (ST2)FE Functional earth connection
 
Included in delivery
 
Actuators must be ordered separately.
The Bowden cable is not included in delivery.
notice:
- Versions AZM400Z-...-BOW may only be used in connection with Bowden cable release ACC-AZM400-BOW-.M-.M, which is available as accessory. Use without the Bowden cable release fitted is not permissible.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 17.02.2019 - 23:53:56h Kasbase 3.3.0.F.64I