Ordering details |
|
Product type description | PS315-T12-H300 |
Article number | 103015124 |
EAN Code | 4030661502816 |
eCl@ss | 27-27-06-01 |
|
Approval |
|
Approval | USA/CAN
CCC
EAC |
|
Classification |
|
Standards | ISO 13849-1 |
B10d Normally-closed contact (NC) | 20.000.000 |
Mission time | 20 Years |
notice |  |
|
Global Properties |
|
Permanent light | PS315 with Roller lever H300 |
Standards | IEC 60947-5-1 |
Compliance with the Directives (Y/N) | Yes |
Suitable for safety functions (Y/N) | Yes |
Actuator type | A To EN 50047 |
Materials |
- Material of the housings | Metal film, Zinkdruckguss |
- Material of the contacts | Silver |
Housing coating | painted |
Housing construction form | Norm construction design |
Weight | 383 g |
|
Mechanical data |
|
Design of electrical connection | Screw connection |
Cable section |
- Min. Cable section | 0,34 mm² |
- Max. Cable section | 1.5 mm² |
Mechanical life | 10.000.000 operations |
Switching frequency | max. 5000 /h |
Design of actuating element | Roller lever H300 |
Positive break force | > 50 N |
Actuating speed for vertical actuation |
- Min. Actuating speed | 60 mm/min |
- Max. Actuating speed | 1 m/s |
|
Ambient conditions |
|
Ambient temperature |
− Min. environmental temperature | −30 °C |
− Max. environmental temperature | +80 °C |
Protection class | IP66, IP67 |
|
Electrical data |
|
Design of control element | 1 Normally open contact (NO), 2 Opener (NC) |
Switching principle | Creep circuit element |
− positive break NC contact |
Number of auxiliary contacts | 1 piece |
Number of safety contacts | 2 piece |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 300 V |
Thermal test current Ithe | 5 A |
Utilisation category | AC-15: 240 V / 3 A, DC-13: 24 V / 3 A |
Required rated short-circuit current | 400 A |
Max. fuse rating | 6 A gG D-fuse (quick-blow) |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 41 mm |
- Height of sensor | 137 mm |
- Length of sensor | 37 mm |
|
Diagram |
|

Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact |
|
Switch travel diagram |
|

Notes Switch travel diagram
Contact closed
Contact open
Setting range
Break point
Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
|
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
21.02.2019 -
00:28:50h Kasbase 3.3.0.F.64I |