• thermoplastic enclosure with foldable latching cover
• Quick connection technology as connection terminals rotated by 45°
• Simple and quick to adjust the control elements by 45°.
• cable entry 1 x M20 x 1,5
• Design to EN 50047

 
 
Ordering details
 
Product type descriptionPS216-T12-K200
Article number103015032
EAN Code4030661501376
eCl@ss27-27-06-01
 
Approval
 
Approval USA/CAN
CCC
EAC
 
Classification
 
StandardsISO 13849-1
B10d Normally-closed contact (NC)20.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightPS216 with Offset roller lever K200
StandardsIEC 60947-5-1
Compliance with the Directives (Y/N)Yes
Suitable for safety functions (Y/N)Yes
Actuator typeE To EN 50047
Materials
- Material of the housingsMetal film, Zinkdruckguss
- Material of the contactsSilver
Housing coatingNone
Housing construction formNorm construction design
Weight62 g
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section0,34 mm²
- Max. Cable section1.5 mm²
Mechanical life10.000.000 operations
Switching frequencymax. 5000 /h
Design of actuating elementOffset roller lever K200
Positive break force> 40 N
Actuating speed for vertical actuation
- Min. Actuating speed60 mm/min
- Max. Actuating speed1 m/s
 
Ambient conditions
 
Ambient temperature
− Min. environmental temperature−30 °C
− Max. environmental temperature+80 °C
Protection classIP66, IP67
 
Electrical data
 
Design of control element1 Normally open contact (NO), 2 Opener (NC)
Switching principleCreep circuit element
− positive break NC contact
Number of auxiliary contacts1 piece
Number of safety contacts2 piece
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui300 V
Thermal test current Ithe5 A
Utilisation categoryAC-15: 240 V / 3 A, DC-13: 24 V / 3 A
Required rated short-circuit current400 A
Max. fuse rating6 A gG D-fuse
 
Dimensions
 
Dimensions of the sensor
- Width of sensor31 mm
- Height of sensor95 mm
- Length of sensor32.5 mm
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.04.2019 - 04:21:25h Kasbase 3.3.0.F.64I