Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
SLB 240 Series -
• Compact design With integral evaluation
• Range 15 m
• Safe OSSD outputs to PLc
• Automatic start or restart interlock
• Sturdy metal enclosure with M12 connector or cable
• Set-up tool and diagnostic indication

 
 
Ordering details
 
Product type descriptionSLB240-ER-1-LST
Article number103013529
EAN Code4030661492452
eCl@ss27-27-27-01
 
Approval
 
Approval
 
Classification
 
StandardsEN ISO 13849-1, EN 62061
PLup c
Control categoryup 2
PFH value1.5 x 10−8 1/h
SILup 1
Mission time20 Years
 
Global Properties
 
Permanent lightSLB240
StandardsEN 61496-1; EN 61496-2
Compliance with the Directives (Y/N) Yes
Operating resource protection classProtection class 3
Safety type in accordance with IEC 61496-12
Materials
- Material of the housingsAluminium
Weight150
Beam coding (Y/N)Yes
Beam coding1
Protection field height
Range of the protection field300 … 15.000
Reaction time7 … 22
Wave length of the sensors880
Fade-out is possible (Y/N)No
Override possible (Y/N)No
reduced resolution (Y/N)No
Clock control possible (Y/N)No
Muting possible (Y/N)No
Restart block (Y/N)Yes
Master/slave functionNo
Cascadable (Y/N)No
Monitoring function of downstream devices (Y/N)Yes
Recommended safety-monitoring modulePSC1,
SRB-E-204ST
 
Mechanical data
 
Detection ability for test bodies40; V = 1.6 M/S
Number of beams1
Design of electrical connection
- Wiring of the transmittercable with connector M12, 4-pole
- Wiring of the receivercable with connector M12, 5-pole
Cable length100
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30
- Max. environmental temperature+50
Storage and transport temperature
- Min. Storage and transport temperature−30
- Max. Storage and transport temperature+70
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of output switching element OSSDPNP
Power consumption
- Power consumption Transmitter< 5
- Power consumption Receiver< 5
Voltage typeDC
Switching voltage of the OSSD in high state24 ±10
 
Outputs
 
Max. output current at secured output200
 
Electrical data - Safety outputs
 
Number of secure semi-conductor outputs2
Number of secure outputs with contact
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- 7-segment displayNo
- Status and diagnosticsYes
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions
- Width27.8
- Height72
- Length33

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 17.04.2019 - 14:56:39h Kasbase 3.3.0.F.64I