Ordering details |
|
Product type description | AZM201B-SK-T-1P2PW-A |
Article number | 1030134911 |
EAN Code | 4030661493343 |
eCl@ss | 27-27-26-03 |
|
Approval |
|
Approval | 

 |
|
Classification |
|
Interlocking function: |
Standards | EN ISO 13849-1, IEC 61508, IEC 62061 |
PL | e |
Control category | 4 |
PFH value | 1.9 x 10−9 / h |
PFD value | 1.6 x 10−4 |
SIL | Suitable for SIL 3 applications |
Mission time | 20 Years |
Guard locking function: |
Standards | − |
PL | − |
Control category | − |
PFH value | − |
PFD value | − |
SIL | − |
Mission time | − |
|
Global Properties |
|
Permanent light | AZM201 |
Standards | IEC 60947-5-1, IEC 60947-5-3, ISO 14119, ISO 13849-1, IEC 61508, IEC 62061 |
Compliance with the Directives (Y/N)  | Yes |
Suitable for safety functions (Y/N) | Yes |
Protection rating | III |
Series-wiring | up to 31 components |
Length of the sensor chain | 200 m |
Active principle | RFID |
Duty cycle | 100 |
Coding levels according to ISO 14119 | low |
Coding | Universal coding |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
Housing coating | None |
Weight | 590 |
Guard locking monitored (Y/N) | No |
Actuator monitored (Y/N) | Yes |
Idle assignable pushbutton and LED (Y/N) | No |
Response time |
Actuator | ≤ 100 |
Duration of risk | < 200 |
Time to readiness | < 4000 |
Recommended actuator | AZ/AZM201-B1, AZ/AZM201-B30 |
- Actuator | ≤ 100 ms |
- Inputs | ≤ 0,5 ms |
|
Mechanical data |
|
Design of electrical connection | Screw connection |
Cable section |
- Min. Cable section | 0,25 mm² |
- Max. Cable section | 1.5 mm² |
AWG-Number | 23 - 15 |
Mechanical life | ≥ 1.000.000 operations |
notice | All indications about the cable section are including the conductor ferrules. |
restistance to shock | 30 / 11 |
Resistance to vibration | 10 … 150 HZ, Amplitude 0,35 mm |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | Yes |
Emergency release (Y/N) | No |
Latching force | 30 |
Clamping force | 2000 |
Max. Actuating speed | ≤ 0,2 |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +60 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Relative humidity | 30… 95 |
- non-condensing |
Protection class | IP66, IP67 to IEC 60529 |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage | 0,8 |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electrical data |
|
Number of auxiliary contacts | 0 |
Number of safety contacts | 2 |
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Power to unlock | No |
Power to lock | Yes |
Supply voltage |
- Min. supply voltage | 20.4 V DC |
- Max. supply voltage | 26.4 V DC |
Switch frequency | 1 |
Rated insulation voltage | 32 V DC |
Operating current | 1.2 A |
Utilisation category | DC-13 |
No-load current | 0,6 A |
Device insulation | ≤ 4 A if used in accordance with UL 508 |
|
Electrical data - Safety inputs |
|
Safety inputs | X1 and X2 |
Rated operating voltage | -3 … 5 (Low) 15 … 30 (High) |
Operating current | typically 2 at 24 |
|
Electrical data - Safety outputs |
|
Safety outputs | Y1 and Y2 |
Fuse rating | short-circuit proof, p-type |
Rated operating voltage | 0 … 4 under |
Residual current | ≤ 0,5 |
Operating current | max. each 0,25 A |
Utilisation category | DC-13 |
|
Electrical data - Diagnostic output |
|
Serial diagnostics (Y/N) | No |
Fuse rating | p-type, short-circuit proof |
Operating current | 0,05 A |
Utilisation category | DC-13: 24 V / 0,05 A |
Wiring capacitance for serial diagnostics | - |
diagnostic signals | guard door closed and interlocking device locked |
Operating principle of the diagnostic output | The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
notice | The diagnostic output is not a safety-relevant output! |
|
Electrical data - Solenoid control IN |
|
Rated operating voltage Ue | -3 V … 5 V (Low) 15 V … 30 V (High) |
Operating current Ie | typically 10 mA at 24 V, dynamically 20 mA |
Control command | − |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
LED switching conditions display |
- Supply voltage | green LED |
- switching condition | yellow LED |
- Error functional defect | red LED |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 40 mm |
- Height of sensor | 220 |
- Length of sensor | 50 |
|
notice |
|
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required. |
|
Included in delivery |
|
Included in delivery | AZM201 Triangular key |
Actuators must be ordered separately. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
18.02.2019 -
08:20:35h Kasbase 3.3.0.F.64I |