Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Solenoid interlock  ->  AZM201  ->  AZM201Z-I1-SK-T-1P2PW
 Add Product to the basket. 
AZM201Z-I1-SK-T-1P2PW
• Thermoplastic enclosure
• RFID-technology for needs-based protection against tampering
• Max. length of the sensor chain 200 m
• Self-monitoring series-wiring of 31 sensors
• 3 LEDs to show operating conditions
• Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
• Suitable for hinged and sliding guards
• Intelligent diagnosis
• Manual release
• Individual coding with RFID technology
• Coding level "High" according to ISO 14119
• Power to unlock
• Guard locking monitored

 
 
Ordering details
 
Product type descriptionAZM201Z-I1-SK-T-1P2PW
Article number103013483
EAN Code4030661493268
eCl@ss27-27-26-03
 
Approval
 
Approval TÜV
USA/CAN
EAC
 
Classification
 
Interlocking function:
StandardsEN ISO 13849-1, IEC 61508, IEC 62061
PLe
Control category4
PFH value1.9 x 10−9 / h
PFD value1.6 x 10−4
SILSuitable for SIL 3 applications
Mission time20 Years
Guard locking function:
StandardsISO 13849-1, IEC 61508, IEC 62061
PLd
Control category2
PFH value1.0 x 10−8 / h
PFD value8.9 x 10−4
SILSuitable for SIL 3 applications
Mission time20 Years
 
Global Properties
 
Permanent lightAZM201
StandardsIEC 60947-5-1, IEC 60947-5-3, ISO 14119, ISO 13849-1, IEC 61508, IEC 62061
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Protection ratingIII
Series-wiringup to 31 components
Length of the sensor chain200 m
Active principleRFID
Duty cycle100
Coding levels according to ISO 14119High
CodingIndividual coding
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight590
Guard locking monitored (Y/N)Yes
Actuator monitored (Y/N)No
Idle assignable pushbutton and LED (Y/N)No
Response time
Actuator≤ 100
Duration of risk< 200
Time to readiness< 4000
Recommended actuatorAZ/AZM201-B1, AZ/AZM201-B30
- Actuator≤ 100 ms
- Inputs≤ 0,5 ms
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section0,25 mm²
- Max. Cable section1.5 mm²
AWG-Number23 - 15
Mechanical life≥ 1.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
restistance to shock30 / 11
Resistance to vibration10 … 150 HZ, Amplitude 0,35 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)Yes
Emergency release (Y/N)No
Latching force30
Clamping force2000
Max. Actuating speed≤ 0,2
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+60
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30… 95
- non-condensing
Protection classIP66, IP67 to IEC 60529
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Power to unlockYes
Power to lockNo
Supply voltage
- Min. supply voltage20.4 V DC
- Max. supply voltage26.4 V DC
Switch frequency1
Rated insulation voltage32 V DC
Operating current1.2 A
Utilisation categoryDC-13
No-load current0,6 A
Device insulation≤ 4 A if used in accordance with UL 508
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
Rated operating voltage-3 … 5 (Low)
15 … 30 (High)
Operating currenttypically 2 at 24
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof, p-type
Rated operating voltage0 … 4 under
Residual current≤ 0,5
Operating currentmax. each 0,25 A
Utilisation categoryDC-13
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)No
Fuse ratingp-type, short-circuit proof
Operating current0,05 A
Utilisation categoryDC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnostics-
diagnostic signalsguard door closed and interlocking device locked
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!
 
Electrical data - Solenoid control IN
 
Rated operating voltage Ue-3 V … 5 V (Low)
15 V … 30 V (High)
Operating current Ietypically 10 mA at 24 V, dynamically 20 mA
Control command
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltagegreen LED
- switching conditionyellow LED
- Error functional defectred LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40 mm
- Height of sensor220
- Length of sensor50
 
notice
 
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required.
 
Included in delivery
 
Included in deliveryAZM201
Triangular key
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 16.06.2019 - 05:25:39h Kasbase 3.3.0.F.64I