Ordering details |
|
Product type description | AZM300B-I2-ST-SD2P-T |
Article number | 103008179 |
EAN Code |
eCl@ss | 27-27-26-03 |
|
Approval |
|
Approval | 

ECOLAB
 |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508 |
PL | e |
Control category | 4 |
SIL | 3 |
Mission time | 20 Years |
PFH value | 5.2 x 10−10 /h |
|
Global Properties |
|
Permanent light | AZM300 |
Standards | EN 60947-5-1, IEC 60947-5-3, IEC 61508, EN ISO 13849-1 |
Compliance with the Directives (Y/N)  | Yes |
Suitable for safety functions (Y/N) | Yes |
Series-wiring | Yes |
Length of the sensor chain | 200 |
Active principle | RFID |
Coding levels according to ISO 14119 | High |
Coding | Individual coding, multiple teaching |
Duty cycle | 100 |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
Housing coating | None |
Weight |
Guard locking monitored (Y/N) | No |
Actuator monitored (Y/N) | Yes |
Idle assignable pushbutton and LED (Y/N) | No |
Reaction time | < 120 |
Duration of risk | < 200 |
Time to readiness | 5 s |
Recommended actuator | AZ/AZM300-B1 |
|
Mechanical data |
|
Design of electrical connection | Connector M12, 8-pole, A-coded |
Mechanical life | ≥ 1.000.000 operations |
notice - Mechanical life (when used as door stop) | ≥ 50.000 operations for guards ≤ 5 kg; actuating speed ≤ 0,5 m/s |
Switch distance | 2 |
Ensured switch distance ON | 1 |
Ensured switch distance OFF | 20 |
restistance to shock | 30 / 11 |
Resistance to vibration | 10 … 150 HZ, Amplitude 0,35 mm |
Emergency unlocking device (Y/N) | Yes |
Manual release (Y/N) | No |
Emergency release (Y/N) | No |
Latching (Y/N) | Yes |
Latching force | 25 / 50 |
Clamping force F | 1150 N |
Actuator and interlock misalignment | ≤ 2 |
fixing screws | 2 x M6 |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | 0 |
- Max. environmental temperature | +60 |
Storage and transport temperature |
- Min. Storage and transport temperature | −10 |
- Max. Storage and transport temperature | +90 |
Protection class | IP66, IP67, IP69 to IEC 60529 |
Protection rating | II |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage | 0,8 |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electrical data |
|
Number of auxiliary contacts | 0 |
Number of safety contacts | 2 |
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Power to unlock | Yes |
Power to lock | No |
Supply voltage (stabilised PELV) | 24 −15 / +10 |
Switch frequency | 0,5 |
Operating current | 100 (without load) |
Rated insulation voltage | 32 VDC |
Operating current | 1 A |
Utilisation category | DC-13 |
Required rated short-circuit current | 100 A |
Device insulation | 2 A |
notice | Cable length and cable section alter the voltage drop depending on the output current |
|
Electrical data - Safety inputs |
|
Safety inputs | X1 and X2 |
Switching thresholds | −3 … 5 ( Low) 15 … 30 ( High) |
Operating current | 5 / 24 |
|
Electrical data - Safety outputs |
|
Safety outputs | Y1 and Y2 |
Design of control output | short-circuit proof, p-type |
Rated operating voltage | 0 … 4 under Supply voltage |
Residual current | ≤ 0,5 |
Operating current | 0,25 A |
Utilisation category | DC-12, DC-13 |
Test impulse width | < 0,5 |
Test frequency | 1 |
|
Electrical data - Diagnostic output |
|
Serial diagnostics (Y/N) | Yes |
Design of control output | short-circuit proof, p-type |
Rated operating voltage | 0 … 4 under Supply voltage |
Operating current | 0,05 A |
Utilisation category | DC-12, DC-13 |
Wiring capacitance for serial diagnostics | 50 |
diagnostic signals | to SD-interface |
Operating principle of the diagnostic output | The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
notice | The diagnostic output is not a safety-relevant output! |
|
Electrical data - Solenoid control IN |
|
Switching thresholds | −3 … 5 (Low) 15 … 30 (High) |
Operating current | 10 / 24 |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
LED switching conditions display |
- Supply voltage | green LED |
- switching condition | yellow LED |
- Error functional defect | red LED |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 85 |
- Height of sensor | 126 |
- Length of sensor | 35 |
|
Pin assignment |
|
1 | A1 Supply voltage |
2 | X1 Safety input 1 |
3 | A2 GND |
4 | Y1 Safety output 1 |
5 | OUT Diagnostic output |
6 | X2 Safety input 2 |
7 | Y2 Safety output 2 |
8 | IN Solenoid control |
|
notice |
|
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required. |
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. |
For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
19.02.2019 -
22:58:19h Kasbase 3.3.0.F.64I |