Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
 Add Product to the basket. 
MS-AZ 200ST-T-1P2P-2568
NOTICE: Available until 2020.12.31 (substitute: AZ201)
• Thermoplastic enclosure
• Connector M23, 8+1-pole
• Idle assignable pushbutton and LED
• Max. length of the sensor chain 200 m
• Self-monitoring series-wiring of 31 sensors
• 3 LEDs to show operating conditions
• Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
• Intelligent diagnosis

 
 
Ordering details
 
Product type descriptionMS-AZ 200ST-T-1P2P-2568
Article number103006853
EAN Code
eCl@ss27-27-26-02
 
Approval
 
Approval USA/CAN
TÜV
EAC
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLe
Control category4
PFH4.0 x 10-9/h
SIL3
Mission time TM20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightAZ 200
StandardsIEC 60947-5-3, IEC 61508, EN ISO 13849-1, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Series-wiringup to 31 components
Length of the sensor chainmax. 200 m
Active principleNon-contact
Duty cycle ED100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight400
Actuator monitored (Y/N)Yes
Idle assignable pushbutton and LED (Y/N)Yes
Reaction time≤ 60
Duration of risk> 120
Time to readiness4000
Recommended actuatorAZ/AZM 200-B1
 
Mechanical data
 
Design of electrical connectionConnector M23, 12-pole
Mechanical life≥ 1.000.000 operations
Switch distance Sn6.5 mm
Ensured switch distance ON Sao4 mm
Ensured switch distance OFF Sar30 mm
hysteresismax. 1.5
Repeat accuracy R R< 0,5 mm
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)No
Emergency release (Y/N)No
Latching force30
Max. Actuating speed≤ 0,2
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30… 95
- non-condensing
Protection classIP67 to IEC/EN 60529
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Switch frequency1
Rated insulation voltage Ui32 VDC
Rated operating voltage Ue
- Min. Rated operating voltage20.4 VDC
- Max. Rated operating voltage26.4 VDC
Operating current Ie0,7 A
Utilisation categoryDC-13
No-load current I00,1 A
Device insulation≤ 4 A
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
Rated operating voltage Ue- 3 V … 5 V (Low)
15 V … 30 V (High)
Operating current Ie> 2 mA / 24 V
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof
Design of control outputp-type
Rated operating voltage0 V … 4 V under Ue
Residual current Ir≤ 0,5 mA
Operating current Ie0,25 A
Utilisation categoryDC-13: 24 V / 0,25 A
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)No
Fuse ratingshort-circuit proof
Design of control outputp-type
Operating current Ie0,05 A
Utilisation categoryDC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnostics-
diagnostic signalsguard door closed
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltagegreen LED
- switching conditionyellow LED
- Error functional defectred LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor220
- Length of sensor50
 
Pin assignment
 
1A1 Supply voltage UB
2X1 Safety input 1
3A2 GND
4Y1 Safety output 1
5OUT Diagnostic output
6X2 Safety input 2
7Y2 Safety output 2
8IN serial diagnostic input
9without function
 
Included in delivery
 
Actuators must be ordered separately.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 19.06.2019 - 02:56:57h Kasbase 3.3.0.F.64I