Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Solenoid interlock  ->  AZM 200D  ->  MS-AZM 200D-ST3-T-1P2P2P-2568
 Add Product to the basket. 
MS-AZM 200D-ST3-T-1P2P2P-2568
NOTICE: Available until 2020.12.31 (substitute: AZM201D)
• Thermoplastic enclosure
• Electronic contact-free, coded system
• Max. length of the sensor chain 200 m
• 3 LEDs to show operating conditions
• Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
• Intelligent diagnosis
• Manual release
• Guard locking monitored

 
 
Ordering details
 
Product type descriptionMS-AZM 200D-ST3-T-1P2P2P-2568
Article number103006851
EAN Code
eCl@ss27-27-26-03
 
Approval
 
Approval
 
Classification
 
Safety guard monitoring Y1 and Y2
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLbis e
Control categorybis 4
PFH value4.0 x 10-9/
SILbis 3
Mission time20 Years
ClassificationPDF-M
ClassificationPDF-M
Locking monitoring Y3 and Y4
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLup d
Control categorybis 3
PFH value1.0 x 10 −7
SILup 2
Mission time20 Years
 
Global Properties
 
Permanent lightAZM 200D
StandardsEN 60947-5-1, IEC 61508, EN ISO 13849-1, IEC 60947-5-3
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Active principleinductive
Duty cycle100
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight590
Guard locking monitored (Y/N)Yes (Sicherheitsausgänge Y3, Y4)
Actuator monitored (Y/N)Yes (Sicherheitsausgänge Y1, Y2)
Idle assignable pushbutton and LED (Y/N)No
Reaction time≤ 60
Duration of risk< 120
Time to readiness< 4000
Recommended actuatorAZ/AZM 200-B1
 
Mechanical data
 
Design of electrical connectionConnector M23, 12-pole
Cable section
- Min. Cable section0,25
- Max. Cable section1.5
AWG-Number23 - 15
Mechanical life≥ 1.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
restistance to shock30 / 11
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)Yes
Emergency release (Y/N)No
Latching force30
Clamping force2000
Max. Actuating speed≤ 0,2
Cable length200
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+60
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Protection classIP67 to IEC/EN 60529
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Number of auxiliary contacts0
Number of safety contacts4
Cross circuit/short circuit recognition possible (Y/N)Yes
Power to unlockYes
Power to lockNo
Supply voltage
- Min. supply voltage20.4 V DC
- Max. supply voltage26.4 V DC
Switch frequency1
Rated insulation voltage32 V DC
Operating current1.2 A
Utilisation categoryDC-12, DC-13
No-load current0,5 A
Device insulation
- screw or spade terminals≤ 4 A if used in accordance with UL 508
- Connector M12≤ 2 A
- Connector M23≤ 4 A
 
Electrical data - Safety outputs
 
Safety outputsY1, Y2, Y3, Y4
Fuse ratingshort-circuit proof, p-type
Rated operating voltage0 … 4 under Supply voltage
Residual current≤ 0,5
Operating currentY1, Y2: 0,25 A
Y3, Y4: 0,1 A
Utilisation categoryDC-13
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)No
Fuse ratingp-type, short-circuit proof
Operating current0,1 A
Utilisation categoryDC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnostics-
diagnostic signalsguard door closed
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!
Residual current through outputs Y3, Y4, OUT:IY3+ IY4 + OUT ≤ 0,1 A
 
Electrical data - Solenoid control IN
 
Rated operating voltage- 3 … 5 ( Low)
15 … 30 ( High)
Operating currenttypically 10 / 24 , dynamically 20
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltagegreen LED
- switching conditionyellow LED
- Error functional defectred LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor220
- Length of sensor50
 
notice
 
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required.
 
Included in delivery
 
Included in deliveryAZM 200
Triangular key
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 15.06.2019 - 19:34:28h Kasbase 3.3.0.F.64I