Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Thermoplastic enclosure
• Symmetric enclosure
• Protection class IP66, IP67
• connector plug M12, right
• Snap action 1 Normally open contact (NO) / 2 Opener (NC)

 
 
Ordering details
 
Product type descriptionPS116-Z12-STR-S200
Article number103006626
EAN Code
eCl@ss27-27-26-01
 
Approval
 
Approval

 
Classification
 
StandardsISO 13849-1
B10d Normally-closed contact (NC)20.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightPS116 Druckbolzen S200
StandardsIEC 60947-5-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Actuator typeB to EN 50047
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, zinc die-cast, chromated
- Material of the contactsSilver
Housing coatingNone
Housing construction formNorm construction design
Weight50 g
 
Mechanical data
 
Design of electrical connectionConnector M12, 6-pole
Connectorright
Mechanical life10.000.000 operations
Switching frequencymax. 5000 /h
Design of actuating elementPlunger S200
Actuating forcemin. 10 N
Bounce duration< 3 ms
Switchover time< 5.5 ms
Positive break force40 N
Actuating speed for vertical actuation
- Min. Actuating speed10 mm/min
- Max. Actuating speed1 m/s
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30 °C
- Max. environmental temperature+80 °C
Protection classIP66, IP67
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleSnap switch element
- positive break NC contact
Number of auxiliary contacts1 piece
Number of safety contacts2 piece
Rated impulse withstand voltage Uimp0,8 kV
Rated insulation voltage Ui30 V
Thermal test current Ithe2 A
Utilisation categoryDC-13: 24 V / 1,5 A
Required rated short-circuit current1000 A
Max. fuse rating6 A gG D-fuse (quick-blow)
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor31 mm
- Height of sensor64 mm
- Length of sensor16.6 mm
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 22.04.2019 - 18:10:35h Kasbase 3.3.0.F.64I