Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
 Add Product to the basket. 
PS116-Z11-LR200-J200
• Thermoplastic enclosure
only for positioning tasks
• Lever angle adjustable in 15° steps
• Symmetric enclosure
• Protection class IP66, IP67
• Actuator heads can be repositioned by 8 x 45°
• Pre-wired cable right, 2
• Snap action 1 Normally open contact (NO) / 1 Opener (NC)

 
 
Ordering details
 
Product type descriptionPS116-Z11-LR200-J200
Article number103006581
EAN Code
eCl@ss27-27-26-01
 
Approval
 
Approval

 
Classification
 
StandardsISO 13849-1
B10d Normally-closed contact (NC)20.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightPS116 Stabschwenkhebel J200
StandardsIEC 60947-5-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)No
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, zinc die-cast, chromated
- Material of the contactsSilver
Housing coatingNone
Housing construction formNorm construction design
Cable colourGrey
Cable typeLiYY
Weight160 g
 
Mechanical data
 
Design of electrical connectionCable, 4-pole
Connectorright
Conductors4 x 0,5 mm²
Mechanical life10.000.000 operations
Switching frequencymax. 5000 /h
Design of actuating elementRod lever J200
Actuating forcemin. 15 Ncm
Bounce duration< 3 ms
Switchover time< 5.5 ms
Actuating speed for vertical actuation
- Min. Actuating speed687 mm/min
- Max. Actuating speed1 m/s
Cable length2 m
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30 °C
- Max. environmental temperature+80 °C
Protection classIP66, IP67
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleSnap switch element
Number of auxiliary contacts1 piece
Number of safety contacts1 piece
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui300 V
Thermal test current Ithe5 A
Utilisation categoryAC-15: 240 V / 3 A,
DC-13: 24 V / 1,5 A
Required rated short-circuit current1000 A
Max. fuse rating6 A gG D-fuse (quick-blow)
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor31 mm
- Height of sensor169 mm (Rod centered)
- Length of sensor16.6 mm
Staff diameter6 mm
Lever length200 mm
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 16.06.2019 - 12:02:38h Kasbase 3.3.0.F.64I