Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Safety sensor, electronic
• Thermoplastic enclosure
• Universal repeatedly teachable or individual coding because of the RFID technology
• I-variants with coding level HIGH to ISO 14119
• Small body, high switching distance
• Protection class IP65 / IP67
• Universal coding with RFID technology

 
 
Ordering details
 
Product type descriptionRSS260-ST-AS
Article number103004638
EAN Code
eCl@ss27-27-24-02
 
Approval
 
Approval

 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLe
Control category4
PFH value3.93 x 10-10 /
PFD value6.89 x 10- 5
SIL3
Mission time20 Years
 
Global Properties
 
Permanent lightRSS260 AS
StandardsEN 50295, ISO 14119, IEC 61508, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Number of actuating directions2
Active principleRFID
Coding levels according to ISO 14119low
CodingUniversal coding
Materials
- Material of the housingsThermoplastic hotmelt
Weight29
Coding available (Y/N)Yes
Response time< 100
Duration of risk< 200
Time to readiness≤ 2 s
Switch frequency≤ 1
Recommended actuatorRST260-1
 
Mechanical data
 
Design of electrical connectionConnector M8, 4-pole, A-coded
Switch distance12
9 (in case of approach from side)
Ensured switch distance ON10
6 (in case of approach from side)
Ensured switch distance OFF18
15 (in case of approach from side)
hysteresis< 2 mm
Repeat accuracy R< 0,5 mm
noticeMinimum distance between two safety sensors 100 mm
restistance to shock30 / 11
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Latching (Y/N)No
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+60
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Protection ratingIII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8
- Rated insulation voltage32
- Overvoltage categoryIII
- Degree of pollution3
Protection classIP65 / IP67 to IEC/EN 60529
 
Electrical data - AS interface
 
AS-i Supply voltage18 … 31.6 VDC, Protection against polarity reversal
AS-i operating current≤ 100
AS-i Device insulationinternally short-circuit proof
AS-i SpecificationSafety Slave
- versionV 2.1
- ProfileS-0.B.F.E
AS-i Inputs
- Channel 1Data bits DI 0/DI 1= dynamic code transmission
- Channel 2Data bits DI 2/DI 3= dynamic code transmission
AS-i OutputsDO 0 … DO 3 not used
AS-i Parameter bits
- P0Actuator in
- P1Hysteresis area notification (FID)
- P2Tampering protection time active (FID)
- P3device error (FID)
AS-i input module address0
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device
noticeSet the parameter outputs to "1111" (0xF)
FID: periphery error
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
(1) green/red LED (AS-i duo LED)Supply voltage / Communication error / slave address = 0 / periphery error detected / Tampering protection time active
(2) yellow LEDDevice status (Enabling status) / Hysteresis area notification / device error
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor29.5
- Length of sensor18
 
Included in delivery
 
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal