Ordering details |
|
Product type description | RSS16-I2-D-ST8H |
Article number | 103004339 |
EAN Code |
eCl@ss | 27-27-24-01 |
|
Approval |
|
Approval | 

 |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508, IEC 60947-5-3, EN 62061 |
PL | bis e |
Control category | bis 4 |
PFH | 6.3 x 10−11/h |
SIL | 3 |
Mission time | 20 Years |
|
Global Properties |
|
Permanent light | RSS16 |
Standards | IEC 60947-5-3 |
Compliance with the Directives (Y/N)  | Yes |
Suitable for safety functions (Y/N) | Yes |
Function | Sensor for series wiring |
Length of the sensor chain | 200 |
Mounting | 2 x M5, Cylinder head screw |
Active principle | RFID |
Coding | Individual coding, multiple teaching |
Coding levels according to ISO 14119 | High |
Materials |
- Material of the active surface | Plastic, glass-fibre reinforced thermoplastic |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Housing construction form | Block |
Weight |
Input for enabling pushbutton, suitable for automatic start (Y/N) | No |
Input for reset pushbutton, with edge monitoring (Y/N) | No |
Diagnostic output (Y/N) | Yes |
Reaction time | ≤ 100 |
Duration of risk | ≤ 200 |
Time to readiness | ≤ 2 |
Cascadable (Y/N) | Yes |
Series-wiring | unlimited |
Recommended actuator | RST16-1, RST-U-2 |
|
Mechanical data |
|
Design of electrical connection | Connector M12, 8-pole |
mechanical installation conditions | not flush |
Actuating planes | front side, rear, Actuation from top |
Active area | lateral, front side, cover-side |
Switch distance | 15 |
Ensured switch distance ON | 12 |
Ensured switch distance OFF | 30 |
hysteresis | 2 mm |
Repeat accuracy R | < 0,5 mm |
notice | The actuator mounting centric to the active sensor surface enables a max. height misalignment (X) of ± 27 mm in the vicinity. The axial misalignment (Y) amounts to max. ± 9 mm. see drawing: Operating principle
Minimum distance between two safety sensors 250 mm |
restistance to shock | 30 / 11 |
Resistance to vibration | - |
Latching (Y/N) | No |
Latching force | - |
Tightening torque for nuts | 2 |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +70 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Protection class | IP65, IP66, IP67 to IEC/EN 60529 |
Protection rating | - |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage | 0,8 |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electromagnetic compatibility (EMC) |
|
EMC rating | to IEC 60947-3 |
Interfering radiation | to IEC 61000-6-4 |
|
Electrical data |
|
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Voltage type | DC |
Switch frequency | 1 |
Rated insulation voltage | 32 VDC |
Rated operating voltage (stabilised PELV) |
- Min. Rated operating voltage | 20.4 VDC |
- Max. Rated operating voltage | 26.4 VDC |
Operating current | 2.1 A |
No-load current | 0,1 A |
Required rated short-circuit current | 100 A |
notice | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
|
Electrical data - Safety inputs |
|
Safety inputs | X1 and X2 |
Rated operating voltage | 24 −15 / +10 |
|
Electrical data - Safety outputs |
|
Safety outputs | Y1 and Y2 |
Fuse rating | short-circuit proof |
Design of control output | p-type |
Number of secure semi-conductor outputs | 2 |
Max. output current at secured output | 1 A |
Rated operating voltage | ( − 1) |
Residual current | ≤ 0,5 |
Operating current | 1 A |
Minimum operating current | 0,5 |
- Ambient temperature -25°C ... +70°C | ≤ 0,25 A |
- Ambient temperature -25°C ... +65°C | ≤ 0,5 A |
- Ambient temperature -25°C ... +55°C | ≤ 1 A |
Utilisation category | DC-12: 24 V / 0,25 A DC-13: 24 V / 0,25 A |
Voltage drop | < 1 |
|
Electrical data - Diagnostic output |
|
Serial diagnostics (Y/N) | Yes |
Fuse rating | short-circuit proof |
Design of control output | p-type |
Number of semi-conductor outputs with signaling function | 1 |
Rated operating voltage | ( − 2) |
Operating current | 0,05 A |
Voltage drop | < 2 |
Utilisation category | DC-12: 24 V / 0,05 A DC-13: 24 V / 0,05 A |
Wiring capacitance for serial diagnostics | 50 |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
Multi-coloured LED | green red |
Number of LED´s | 2 |
- green LED | Supply voltage |
- red LED | Error |
- yellow LED | switching condition |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 52 |
- Height of sensor | 30 |
- Length of sensor | 91 |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
20.02.2019 -
20:10:29h Kasbase 3.3.0.F.64I |