Ordering details |
|
Product type description | AZM400Z-ST-1P2P |
Article number | 103003590 |
EAN Code | 4030661472577 |
eCl@ss | 27-27-26-03 |
|
Approval |
|
Approval | 

|
|
Classification |
|
Interlocking function: |
Standards | ISO 13849-1, IEC 61508 |
PL | up e |
Control category | up 4 |
PFH value | 1.0 x 10−9 / h |
PFD value | 9.0 x 10−5 |
SIL | up 3 |
Mission time | 20 Years |
Guard locking function: |
Standards | ISO 13849-1, IEC 61508 |
PL | up e |
Control category | up 4 |
PFH value | 1.8 x 10−9/h |
PFD value | 1.6 x 10−4 |
SIL | up 3 |
Mission time | 20 Years |
|
Global Properties |
|
Permanent light | AZM400 |
Standards | IEC 60947-5-1, ISO 14119, ISO 13849-1, IEC 61508 |
Compliance with the Directives (Y/N)  | Yes |
Suitable for safety functions (Y/N) | Yes |
Active principle | Magnetic field / RFID |
Coding | Universal coding |
Coding levels according to ISO 14119 | low |
Material of the housings | light alloy die-casting |
Housing coating | None |
Weight | 730 |
Guard locking monitored (Y/N) | Yes |
Idle assignable pushbutton and LED (Y/N) | No |
Reaction time | ≤ 100 |
Time to readiness | ≤ 1.5 s |
Recommended actuator | AZM400-B1 |
|
Mechanical data |
|
Design of electrical connection | Connector M12, 8-pole |
Interlocking principle | bistable |
Mechanical life | ≥ 1.000.000 operations |
- which have a lateral force Fquer = 100 | 100.000 operations |
Switch distance |
- Allowable distance actuator / device incl. angular misalignment | 1 … 7 |
- Minimum distance devices | 30 |
restistance to shock | 30 / 11 |
Resistance to vibration | 10 … 150 HZ, Amplitude 0,35 mm |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | Yes |
Electronic manual release available (Y/N) | No |
Clamping force | 10.000 |
Max. lateral force at bolt return (against locked door) | 300 |
- Notice: does not apply to emergency exit, Bowden cable and manual release |
fixing screws | 2 x M6 (10.9) |
Tightening torque for fixing screws | 8 |
Actuator and interlock misalignment | 2 |
With securing holes for Bowden cable assembly (Y/N) | No |
Tightening torque of the fixing screws Bowden cable | No information |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | 0 |
- Max. environmental temperature | +55 |
Storage and transport temperature |
- Min. Storage and transport temperature | −40 |
- Max. Storage and transport temperature | +85 |
Protection class | IP66, IP67 to IEC/EN 60529 |
Protection rating | III |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage | 0,8 |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electrical data |
|
Number of auxiliary contacts | 0 |
Number of safety contacts | 2 |
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Supply voltage (stabilised PELV) | 24 −15 / +10 |
Switch frequency | 0,3 |
Operating current | 0,1 A |
- During the displacement of the bolt | 0,6 A |
Rated insulation voltage | 32 VDC |
Required rated short-circuit current | 100 A |
Device insulation | 2 A |
Auxiliary voltage (uninterruptible power supply) | No |
Min. open / close cycle (Motor) | 3 |
- with continuous operation min. average cycle time | 20 |
|
Electrical data - Safety outputs |
|
Safety outputs | Y1 and Y2 |
Design of control output | short-circuit proof, p-type |
Rated operating voltage | 24 |
Residual current | ≤ 0,5 |
Operating current | 0,25 A |
Utilisation category | DC-12, DC-13 |
Test impulse width | ≤ 0,4 |
Voltage drop | ≤ 2 |
Test frequency | 1 |
|
Electrical data - Diagnostic output |
|
Serial diagnostics (Y/N) | No |
Design of control output | short-circuit proof, p-type |
Number of diagnostic signals | 1 |
Rated operating voltage | 24 |
Operating current | 0,05 A |
Voltage drop | ≤ 2 |
Utilisation category | DC-12, DC-13 |
Operating principle of the diagnostic output | The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
notice | The diagnostic output is not a safety-relevant output! |
|
Electrical data - Control inputs |
|
Control inputs to unlock | E1 and E2, p-type, E3, n-type |
Switching thresholds | −3 … 5 (Low) 15 … 30 (High) |
Operating current per input | > 10 … < 15 / 24 |
Permissible residual drive current | 1.5 |
Allowable discrepancy time input | ≤ 10 |
Acceptable test impulse on the input signal | < 5 |
- with a test impulse distance of | ≥ 40 |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
LED switching conditions display |
- Supply voltage | green LED |
- switching condition | yellow LED |
- Error functional defect | red LED |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 77.8 |
- Height of sensor | 166.7 |
- Length of sensor | 46.7 |
|
Pin assignment |
|
1 | A1 Supply voltage |
2 | E1 Control input 1 |
3 | A2 GND |
4 | Y1 Safety output 1 |
5 | OUT Diagnostic output |
6 | E3 Control input 3 |
7 | Y2 Safety output 2 |
8 | E2 Control input 2 |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
15.02.2019 -
20:28:46h Kasbase 3.3.0.F.64I |