Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Devices for Ex Zones  ->  Safety sensors  ->  EX-CSS 8-16  ->  EX-CSS 8-16-2P+D-M-L-3G/D
 Add Product to the basket. 
EX-CSS 8-16-2P+D-M-L-3G/D
• Pre-wired cable 7-pole
• Ex certified
• Thermoplastic enclosure
• Non-contact, coded electronic safety sensor for use in areas of zone
with gas and dust-explosion hazard
• Category 3GD, ATEX Zone 2 and 22
• Comfortable diagnostics through sensor LED and electronic signalling output
• High repeat accuracy of the switching points
• Misaligned actuation possible
• Early warning when operating near the limit of the sensor's hysteris range
• Self-monitoring series-wiring of 16 sensors
• Suitable for applications up to PL e / SIL 3

 
 
Ordering details
 
Product type descriptionEX-CSS 8-16-2P+D-M-L-3G/D
Article number103003015
EAN Code
eCl@ss27-27-24-01
 
Approval
 
ApprovalATEX
 
Classification
 
StandardsEN ISO 13849-1, IEC 60947-5-3, IEC 61508
PLup e
Control categorybis 4
PFH6.1 x 10 - 9 /
SILbis 3
Mission time20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightEX-CSS 8-16
StandardsEN 60079-0, EN 60079-15, EN 60079-31
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
FunctionIndividual sensor or end sensor in a series, Sensor for series wiring
Series-wiringup to 16 components
Length of the sensor chain200
Active principleinductive
Materials
- Material of the active surfacePlastic, glass-fibre reinforced thermoplastic
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Housing construction formBlock
Cable colourGrey ( OUT)
Weight
Reaction time< 30
Duration of risk≤ 30
Cascadable (Y/N)Yes
Recommended actuatorCST 16-1
 
Mechanical data
 
Design of electrical connectionCable
- Connector OUT-
- Connector IN-
- Connector IN/OUT7-pole
Cable length2
Conductors0,25
AWG-Number23
mechanical installation conditionsnot flush
Switch distance8
Ensured switch distance ON6
Ensured switch distance OFF11
hysteresis1 mm
Repeat accuracy R< 0,5 mm
restistance to shock30 / 11
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Impact energy-
Tightening torque for nuts-
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+50
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Protection classIP65, IP67 to IEC/EN 60529
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Cross circuit/short circuit recognition possible (Y/N)Yes
Voltage typeDC
Switch frequency3
Rated insulation voltage32 VDC
- Min. Rated operating voltage20.4
- Max. Rated operating voltage26.4
Rated operating voltage( − 0,5)
Residual current≤ 0,5
Operating current0,5 A
Utilisation categoryDC-12: 24 / 0,05 A
DC-13: 24 / 0,05 A
No-load current0,05 A
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of secure semi-conductor outputs2
Max. output current at secured output0,5 A
Residual current≤ 0,5
Operating current0,5 A
Minimum operating current0,5
Utilisation categoryDC-12: 24 / 0,05
DC-13: 24 / 0,05
Voltage drop0,5
 
Electrical data - Diagnostic output
 
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of semi-conductor outputs with signaling function1
Rated operating voltage( − 4)
Operating current0,05 A
Utilisation categoryDC-12: 24 V / 0,05 A
DC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnostics-
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Multi-coloured LEDgreen, red, yellow
 
ATEX
 
EX-markingEX II 3D Ex tc IIIC T80°C Dc X
Ex II 3G Ex nA IIB T6 Gc X
Explosion protection categories for gases3G
Explosion protection Zones for gases2
Explosion protected category for dusts3D
Explosion protection Zones for dusts22
 
Dimensions
 
Dimensions of the sensor
- Width of sensor55
- Height of sensor93
- Length of sensor39.5
- Diameter of sensor-
 
notice
 
Requirements for the safety monitoring module2-channel safety input, suitable for p-type sensors with NO function. The safety monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 2 ms. The safety monitoring module does not need to have a cross-wire short monitoring function.
 
Included in delivery
 
Actuators must be ordered separately.
 
Keywords
 
KeywordsEx, EEx, ATEX, Ex CSS16, EX CSS 16, CSS 16 EX, CSS16ex, CSS 16 ex, ATEX CSS 16

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 18.04.2019 - 14:42:58h Kasbase 3.3.0.F.64I