Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Suitable for mounting to profile systems
• Thermoplastic enclosure
• RFID-technology for needs-based protection against tampering
• 3 different directions of actuation
• Compact design
• 3 LEDs to show operating conditions
• Suitable for hinged and sliding guards
• Series-wiring
• Universal coding with RFID technology
• Connector M12, 8-pole
• Diagnostic output

 
 
Ordering details
 
Product type descriptionAZ300-ST-1P2P
Article number103001462
EAN Code
eCl@ss27-27-26-02
 
Approval
 
Approval

 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLe
Control category4
SIL3
Mission time20 Years
PFH value5.2 x 10−10 /h
 
Global Properties
 
Permanent lightAZ300
StandardsEN 60947-5-1, IEC 60947-5-3, IEC 61508, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Series-wiringYes
Length of the sensor chain200
Active principleRFID
Coding levels according to ISO 14119low
CodingUniversal coding
Duty cycle100
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight
Actuator monitored (Y/N)Yes
Idle assignable pushbutton and LED (Y/N)No
Reaction time< 100
Duration of risk< 200
Time to readiness5
Recommended actuatorAZ/AZM300-B1
 
Mechanical data
 
Design of electrical connectionConnector M12, 8-pole, A-coded
Mechanical life≥ 1.000.000 operations
notice - Mechanical life≥ 50.000 operations for guards 5 kg;
actuating speed
0,5 m/s
Switch distance2
Ensured switch distance ON1
Ensured switch distance OFF20
restistance to shock30 / 11
Resistance to vibration10 … 150 HZ, Amplitude 0,35 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)No
Emergency release (Y/N)No
Latching (Y/N)Yes
Latching force25 / 50
Actuator and interlock misalignment≤ 2
fixing screws2 x M6
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+60
Storage and transport temperature
- Min. Storage and transport temperature−10
- Max. Storage and transport temperature+90
Protection classIP66, IP67 to IEC/EN 60529
IP69K to DIN 40050-9
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Supply voltage (stabilised PELV)24 −15 / +10
Switch frequency0,5
Operating current100 (without load)
Rated insulation voltage32 VDC
Required rated short-circuit current100 A
Device insulation2 A
noticeCable length and cable section alter the voltage drop depending on the output current
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
Switching thresholds−3 … 5 ( Low)
15 … 30 ( High)
Operating current5 / 24
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Design of control outputshort-circuit proof, p-type
Rated operating voltage0 … 4 under Supply voltage
Residual current≤ 0,5
Operating current0,25 A
Utilisation categoryDC-12, DC-13
Test impulse width< 0,5
Test frequency1
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)No
Design of control outputshort-circuit proof, p-type
Rated operating voltage0 … 4 under Supply voltage
Operating current0,05 A
Utilisation categoryDC-12, DC-13
Wiring capacitance for serial diagnostics-
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltagegreen LED
- switching conditionyellow LED
- Error functional defectred LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor85
- Height of sensor100
- Length of sensor35
 
Pin assignment
 
1A1 Supply voltage
2X1 Safety input 1
3A2 GND
4Y1 Safety output 1
5OUT Diagnostic output
6X2 Safety input 2
7Y2 Safety output 2
8without function
 
notice
 
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.
 
Included in delivery
 
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 26.06.2019 - 09:16:56h Kasbase 3.3.0.F.64I