Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Solenoid interlock  ->  AZM300  ->  AZM300B-I2-ST-1P2P
• Suitable for mounting to profile systems
• Thermoplastic enclosure
• RFID-technology for needs-based protection against tampering
• 3 different directions of actuation
• Compact design
• 3 LEDs to show operating conditions
• Suitable for hinged and sliding guards
• Series-wiring
• Manual release
• Repeated individual coding with RFID technology
• Coding level "High" according to ISO 14119
• Connector M12, 8-pole
• Power to unlock
• Actuator monitored
• Diagnostic output

 
 
Ordering details
 
Product type descriptionAZM300B-I2-ST-1P2P
Article number103001415
EAN Code
eCl@ss27-27-26-03
 
Approval
 
Approval

ECOLAB
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLe
Control category4
SIL3
Mission time20 Years
PFH value5.2 x 10−10 /h
 
Global Properties
 
Permanent lightAZM300
StandardsEN 60947-5-1, IEC 60947-5-3, IEC 61508, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Series-wiringYes
Length of the sensor chain200
Active principleRFID
CodingIndividual coding, multiple teaching
Coding levels according to ISO 14119High
Duty cycle100
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight
Guard locking monitored (Y/N)No
Actuator monitored (Y/N)Yes
Idle assignable pushbutton and LED (Y/N)No
Reaction time< 120
Duration of risk< 200
Time to readiness5 s
Recommended actuatorAZ/AZM300-B1
 
Mechanical data
 
Design of electrical connectionConnector M12, 8-pole, A-coded
Mechanical life≥ 1.000.000 operations
notice - Mechanical life (when used as door stop)≥ 50.000 operations for guards ≤ 5 kg;
actuating speed
≤ 0,5 m/s
Switch distance2
Ensured switch distance ON1
Ensured switch distance OFF20
restistance to shock30 / 11
Resistance to vibration10 … 150 HZ, Amplitude 0,35 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)Yes
Emergency release (Y/N)No
Latching (Y/N)Yes
Latching force25 / 50
Clamping force F1150 N
Actuator and interlock misalignment≤ 2
fixing screws2 x M6
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+60
Storage and transport temperature
- Min. Storage and transport temperature−10
- Max. Storage and transport temperature+90
Protection classIP66, IP67, IP69 to IEC 60529
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Power to unlockYes
Power to lockNo
Supply voltage (stabilised PELV)24 −15 / +10
Switch frequency0,5
Operating current100 (without load)
Rated insulation voltage32 VDC
Operating current Ie1 A
Utilisation categoryDC-13
Required rated short-circuit current100 A
Device insulation2 A
noticeCable length and cable section alter the voltage drop depending on the output current
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
Switching thresholds−3 … 5 ( Low)
15 … 30 ( High)
Operating current5 mA / 24 V
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Design of control outputshort-circuit proof, p-type
Rated operating voltage0 … 4 under Supply voltage
Residual current≤ 0,5
Operating current0,25 A
Utilisation categoryDC-12, DC-13
Test impulse width< 0,5
Test frequency1
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)No
Design of control outputshort-circuit proof, p-type
Rated operating voltage Ue0 V … 4 V under Supply voltage UB
Operating current0,05 A
Utilisation categoryDC-12, DC-13
Wiring capacitance for serial diagnostics-
diagnostic signalsguard door closed and interlocking device locked
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!
 
Electrical data - Solenoid control IN
 
Switching thresholds−3 … 5 (Low)
15 … 30 (High)
Operating current10 mA / 24 V
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltagegreen LED
- switching conditionyellow LED
- Error functional defectred LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor85
- Height of sensor100
- Length of sensor35
 
Pin assignment
 
1A1 Supply voltage
2X1 Safety input 1
3A2 GND
4Y1 Safety output 1
5OUT Diagnostic output
6X2 Safety input 2
7Y2 Safety output 2
8IN Solenoid control
 
notice
 
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required.
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.
 
Included in delivery
 
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.04.2019 - 05:41:23h Kasbase 3.3.0.F.64I