Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Foot switch  ->  T2FH 232  ->  T2FH 232-11UEDR/11UEDR
 Add Product to the basket. 
T2FH 232-11UEDR/11UEDR
• double-pedal type
• 2 cable entries M25
• High level of stability
• 2 contacts per pedal
• Protective shield with wide opening

 
 
Ordering details
 
Product type descriptionT2FH 232-11UEDR/11UEDR
Article number101216987
EAN Code4030661410463
eCl@ss27-37-12-18
 
Approval
 
Approval
 
Classification
 
B10d Normally-closed contact (NC)100.000
Mission time20 Years
StandardsEN ISO 13849-1
notice
 
Global Properties
 
Permanent lightT2FH 232
StandardsEN 60947-5-1, DIN VDE 0660-200, BG-GS-ET-15
Compliance with the Directives (Y/N) Yes
Materials
- Material of the housingsAluminium
- Material of the coverAluminium
- Material of the protective shieldAluminium
- Material of the pedalPlastic, glass-fibre reinforced thermoplastic
Housing coatingpowder-coated
Weight
with start/stop function (Y/N)No
Suitable for EMERGENCY-OFF (Y/N)Yes
Protection hood (Y/N)Yes
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section
- Max. Cable section2.5
Mechanical life> 1.000.000 operations
Switching frequency1 /
noticeAll indications about the cable section are including the conductor ferrules.
restistance to shock30 / 11
Resistance to vibration10 … 150 HZ (0,35 mm / 5 g)
Latching (Y/N)Yes
Probing possible (Y/N)Yes
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+ 60
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30 … 95
- non-condensing
- non-icing
Protection type IPIP65 to IEC/EN 60529
Overvoltage categoryIII
Degree of pollution3
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleSlow action with overlapping contacts
Number of shutters (per pedal)1
Number of openers (per pedal)1
Rated impulse withstand voltage6
Rated insulation voltage500
Thermal test current10 A
Utilisation categoryAC-15: 230 V / 4 A,
DC-13: 24 V / 1 A
Required rated short-circuit current1000 A
Max. fuse rating6 A gG D-fuse
 
Dimensions
 
Dimensions
- Width295
- Height189
- Depth274
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.07.2019 - 03:42:12h Kasbase 3.3.0.F.64I