Ordering details |
|
Product type description | BNS 40S-12ZG-C |
Article number | 101215515 |
EAN Code |
eCl@ss | 27-27-24-02 |
|
Approval |
|
Approval | BG
USA/CAN |
|
Classification |
|
Standards | EN ISO 13849-1 |
B10d Normally-closed contact/Normally open contact (NC/NO) | 25.000.000 |
- notice | at max. 20% contact load |
Mission time | 20 Years |
notice |  |
|
Global Properties |
|
Permanent light | BNS 40S |
Standards | IEC 60947-5-3, BG-GS-ET-14 |
Compliance with the Directives (Y/N)  | Yes |
Materials |
- Material of the housings | Stainless steel (V4A) |
- Material of the cable mantle | LiYY |
Weight |
Coding available (Y/N) | Yes |
Concealed threaded holes on the back (Y/N) | Yes |
Monitoring function of downstream devices (Y/N) | No |
Prerequisite evaluation unit | Yes |
Recommended safety-monitoring module | AES 1135, AES 1136, AES 1165, AES 1166, AES 1165-2250, AES 1185, AES 1235, AES 1236, AES 1265, AES 1266, AES 1337, AES 2135, AES 2136, AES 2335, AES 2336, AES 2535, AES 2536, AES 2365, AES 2565, AES 2566, AES 2285, AES 3075, SRB202C., SRB400C., AES 3075 |
Recommended actuator | BPS 40S-1, BPS 40S-2, BPS 40S-1-C, BPS 40S-2-C |
|
Mechanical data |
|
Design of electrical connection | Cable |
Cable length | 1 |
Conductors | 6 x 0,25 |
AWG-Number | 23 |
mechanical installation conditions | not flush |
Active area | Side |
Ensured switch distance ON Sao | 8 mm |
Ensured switch distance OFF Sar | 18 mm |
Type of actuation | Magnet |
Direction of motion | head-on with regard to the active surface |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 55 HZ, Amplitude 1 mm |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +80 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +80 |
Protection class | IP69K |
|
Electrical data |
|
Integrated Safety monitoring module available (Y/N) | No |
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Voltage type | VDC |
Switch frequency | max. 5 HZ |
Switching voltage | 24 max. VDC |
Switching current | 10 mA max. |
Switching capacity | 240 mW max. |
|
Outputs |
|
Design of control output | Other, Reed contakts |
Number of shutters | 1 |
Number of openers | 2 |
|
Electrical data - Safety outputs |
|
Number of secure semi-conductor outputs | 0 |
Number of secure outputs with contact | 0 |
|
Electrical data - Diagnostic output |
|
Number of semi-conductor outputs with signaling function | 0 |
Number of outputs with signaling function that already have a contact | 0 |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
- The LED is illuminated when the guard is closed. |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 88 |
- Height of sensor | 27 |
- Length of sensor | 14.5 |
|
notice |
|
Contact symbols shown for the closed condition of the guard device. |
Contact S21-S22 must be integrated in the safety circuit |
The contact configuration for versions with or without LED is identical. |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
16.02.2019 -
22:07:16h Kasbase 3.3.0.F.64I |