Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Input expander  ->  PROTECT-PE  ->  PROTECT-PE-11-AN-SK
• with antivalent output contacts
• Input expander
• Possibility to connect up to 4 sensors with non-isolated signals, e.g. the CSS products from Schmersal as well as AOPD’s (only PROTECT-PE-02)
• Input for up to 4 sensors per interface e.g.: magnetic safety switches type BNS, emergency stop devices, interlocking devices and others
• 2 safety contacts
• Signalling output for each sensor (monitoring of both circuits of the sensors) and and all sensors (Y5, group signal)

 
Preferred typ
 
Ordering details
 
Product type descriptionPROTECT-PE-11-AN-SK
Article number101210946
EAN Code4030661395548
eCl@ss27-37-19-01
 
Approval
 
Approval USA/CAN
EAC
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, EN 60947-5-1
PLup d (STOP 0)
Control categoryup 3 (STOP 0)
DC> 60% (STOP 0)
CCF> 65 points
PFH value≤ 2 x 10-7/h (STOP 1)
- noticeup to max. 36.500 switching cycles/year and at max. 60% contact load
SILup 2 (STOP 0)
Mission time20 Years
- noticeThe PFH value is applicable for the combinations listed in the table for contact load (K) (current through enabling paths) and switching cycle number (n-op/y).
In case of 365 operating days per year and a 24-hour operation, this results in the specified switching cycle times (t-cycle) for the relay contacts.
Diverging applications on request.
 
Global Properties
 
Permanent lightPROTECT-PE
StandardsIEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-78
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, ventilated
Weight220
Start conditionsAutomatic
Start input (Y/N)No
Feedback circuit (Y/N)No
Start-up test (Y/N)No
Automatic reset function (Y/N)Yes
Reset with edge detection (Y/N)No
Pull-in delay
- ON delay with automatic starttyp. 10 ms
Drop-out delay
- Drop-out delay in case of power failure≤ 60
- Drop-out delay in case of emergency stop≤ 10
 
Mechanical data
 
Connection typeterminals, plug-in
Cable section
- Min. Cable section0,14
- Max. Cable section1.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)Yes
Mechanical life10.000.000 operations
Electrical lifetimeDerating curve available on request
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm, ± 15 %
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−40
- Max. Storage and transport temperature+85
Protection class
- Protection class-EnclosureIP20
- Protection class-TerminalsIP20
- Protection class-ClearanceIP20
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4 kV
- Overvoltage categoryIII To VDE 0110
- Degree of pollution2 To VDE 0110
 
Electromagnetic compatibility (EMC)
 
EMC ratingconforming to EMC Directive
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls21.1
- Max. rated DC voltage for controls28.8
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz21.1
- Max. rated AC voltage for controls, 50 Hz26.4
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz21.1
- Max. rated AC voltage for controls, 60 Hz26.4
Contact resistancemax. 100 mΩ
Power consumptionmax. 1.7 W; plus signalling outputs Y1…Y5
Type of actuationDC
Rated operating voltage Ue24 VDC −12% / +20%, residual ripple max. 10%
Operating current Ie0,075 A; plus signalling outputs Y1…Y5
Electronic protection (Y/N)Yes
Fuse rating for the operating voltageInternal electronic trip, tripping current > 0,3 A
Current and tension on control circuits24 VDC, 10 mA
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)Yes
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)Yes
Number of shutters1
Number of openers1
Input resistanceapprox. 2900 Ω at GND or at Ue
Input signal "1"19 - 28.8 VDC
Input signal "0"0 - 1 VDC
Conduction resistancemax. 40 Ω
 
Outputs
 
Stop category0
Number of safety contacts0
Number of auxiliary contacts2 (13-14; 23- 24)
Number of signalling outputs7 ( Y1-Y5)
Switching capacity
- Switching capacity of the safety contactsmax. 24 VDC, 2 A ohmic (inductive in case of appropriate protective wiring)
- Switching capacity of the signaling/diagnostic outputs24 VDC / 100 mA
Fuse rating
- Protection of the safety contacts2 A slow blow
- Fuse rating for the signaling/diagnostic outputsInternal electronic trip, tripping current > 0,75 A
Utilisation category To EN 60947-5-1DC-13: 24 V / 2 A
Number of undelayed semi-conductor outputs with signaling function0
Number of undelayed outputs with signaling function (with contact)9
Number of delayed semi-conductor outputs with signaling function.0
Number of delayed outputs with signalling function (with contact).0
Number of secure undelayed semi-conductor outputs with signaling function0
Number of secure, undelayed outputs with signaling function, with contact.0
Number of secure, delayed semi-conductor outputs with signaling function0
Number of secure, delayed outputs with signaling function (with contact).0
Outputs with antivalent safety contacts (Y/N)Yes
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s6
LED switching conditions display
- The integrated LEDs indicate the following operating states.
- Position relay K3
- Position relay K1
- Position relay K2
- Position relay K4
- Internal operating voltage Ui
- LED’s or signalling outputs signalise an opened protective device or emergency stops.
- Monitoring effected on both contact circuits of the sensor.
- When the safety guard or the emergency stop circuit is opened, a 24V signal is switched at each output concerned (Y1...Y5) and the assigned LED is lit.
 
Miscellaneous data
 
Applications Emergency-Stop button
Pull-wire emergency stop switches
Guard system
Safety sensor
Safety light curtain
 
Dimensions
 
Dimensions
- Width65.5 mm
- Height126 mm
- Depth61 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
Start level: Depends on the wiring of the safety relay module.
Sensor level: 2-channel control of magnetic safety switches according to EN 60947-5-3
Output level: 2-channel control of a downstream safety relay module
The control recognises cross-short, cable break and earth leakages in the monitoring circuit.
If the inputs S1, S3, S5 and S7 are not used, they have to be bridged to +
If the inputs S2, S4, S6 and S8 are not used, they have to be bridged to -
The safety relay modules must be suitable for signal processing for single or dual-channel floating NC-contacts
Start and actuator configuration has to be effected in accordance with the data sheet
The wiring diagram is shown with guard doors closed and in de-energised condition.
 
Keywords
 
KeywordsPROTECT

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 16.09.2019 - 00:53:16h Kasbase 3.3.0.F.64I