|  Preferred typ |
|
Ordering details |
|
Product type description | MZM 100 B ST2-SD2PREM-A |
Article number | 101211153 |
EAN Code | 4030661389431 |
eCl@ss | 27-27-26-03 |
|
Approval |
|
Approval | EAC
USA/CAN |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508, IEC 60947-5-3, EN 60947-5-1 |
PL | e |
Control category | up 4 |
PFH | 3.5 x 10-9/h |
SIL | up 3 |
Mission time | 20 Years |
Classification | PDF-M |
|
Global Properties |
|
Permanent light | MZM 100 |
Standards | IEC 61508, EN ISO 13849-1, EN ISO 13849-1 |
Compliance with the Directives (Y/N)  | Yes |
Suitable for safety functions (Y/N) | Yes |
Protection rating | III |
Series-wiring | up to 31 components |
Length of the sensor chain | max. 200 m |
− without detriment to the category to EN ISO 13849-1 |
Active principle | inductive |
Duty cycle ED | 100 % |
Coding | Universal coding |
| low |
Duty cycle ED | 100 % |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
Housing coating | None |
Weight | 625 |
Guard locking monitored (Y/N) | No |
Actuator monitored (Y/N) | Yes |
Idle assignable pushbutton and LED (Y/N) | No |
Reaction time | < 150 |
Duration of risk | < 150 |
Time to readiness | < 4000 |
Recommended actuator | MZM 100-B1.1 |
|
Mechanical data |
|
Design of electrical connection | Connector M12, 8-pole |
Mechanical life | ≥ 1.000.000 operations |
notice - Mechanical life | operations for guards ≤ 5 kg; actuating speed ≤ 0,5 m/s |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 150 HZ, Amplitude 0,35 mm |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | No |
Emergency release (Y/N) | No |
Latching (Y/N) | Yes |
electrically adjustable latching force | 30 … 100 |
Permanent magnet (M) typically | 15 N |
Clamping force F |
- typically | 750 N |
- guaranteed | 500 |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +55 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Relative humidity | 30… 95 |
- non-condensing |
- non-icing |
Protection class | IP67 to IEC/EN 60529 |
Protection rating | III |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp | 0,8 kV |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electrical data |
|
Number of auxiliary contacts | 0 |
Number of safety contacts | 2 |
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Power to unlock | No |
Power to lock | Yes |
Supply voltage UB (stabilised PELV) |
- Min. supply voltage | 20.4 V DC |
- Max. supply voltage | 26.4 V DC |
Switch frequency | 1 |
Rated insulation voltage Ui | 32 V DC |
Operating current Ie | 1 A |
Utilisation category | DC-13 |
No-load current I0 | max. 0,5 A |
Required rated short-circuit current | 100 A |
Device insulation | ≤ 2 A (if used in accordance with UL 508) |
notice | Cable length and cable section alter the voltage drop depending on the output current |
|
Electrical data - Safety inputs |
|
Safety inputs | X1 and X2 |
Rated operating voltage Ue | −3 V … 5 V (Low) 15 V … 30 V (High) |
Operating current Ie | > 2 mA / 24 V |
|
Electrical data - Safety outputs |
|
Safety outputs | Y1 and Y2 |
Fuse rating | short-circuit proof, p-type |
Rated operating voltage | 0 V … 4 V under Supply voltage UB |
Residual current Ir | ≤ 0,5 mA |
Operating current Ie | 0,25 A |
Utilisation category | DC-12, DC-13 |
|
Electrical data - Diagnostic output |
|
Serial diagnostics (Y/N) | Yes |
Wiring capacitance for serial diagnostics | 50 |
diagnostic signals | to SD-interface |
Operating principle of the diagnostic output | The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
notice | The diagnostic output is not a safety-relevant output! |
|
Electrical data - Solenoid control IN |
|
Control command | Interlocking the solenoid interlock |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
LED switching conditions display |
- Supply voltage UB | green LED |
- switching condition | yellow LED |
- Error functional defect | red LED |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 40 |
- Height of sensor | 179 |
- Length of sensor | 40 |
|
Pin assignment |
|
1 | A1 Supply voltage UB |
2 | X1 Safety input 1 |
3 | A2 GND |
4 | Y1 Safety output 1 |
5 | OUT serial diagnostic output |
6 | X2 Safety input 2 |
7 | Y2 Safety output 2 |
8 | IN serial diagnostic input |
9 | without function |
|
notice |
|
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required. |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
17.02.2019 -
19:56:48h Kasbase 3.3.0.F.64I |