Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
NOTICE: Not available! (Replacement: RSS16)
• Connector M12, 4-pole
• Thermoplastic enclosure
• Electronic contact-free, coded system
• Misaligned actuation possible
• 55 mm x 93 mm x 39.5 mm
• High repeat accuracy of the switching points
• Max. length of the sensor chain 200 m
• Early warning when operating near the limit of the sensor's hysteris range
• Self-monitoring series-wiring of 16 sensors
• 2 short-circuit proof PNP safety outputs

 
Preferred typ
 
Ordering details
 
NOTICE: Not available! (Replacement: RSS16)
Product type descriptionCSS 8-16-2P-E-LST
Article number101210575
EAN Code4030661388915
eCl@ss27-27-24-01
 
Approval
 
Approval BG
USA/CAN
EAC
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLup e
Control categorybis 4
PFH2.5 x 10−9/h
SILbis 3
Mission time20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightCSS 16
StandardsIEC 61508, IEC 60947-5-3, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
FunctionIndividual sensor or end sensor in a series
Series-wiringup to 16 components
Length of the sensor chainmax. 200 m
Active principleinductive
Materials
- Material of the active surfacePlastic, glass-fibre reinforced thermoplastic
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Housing construction formBlock
Cable colourGrey (OUT)
Weight
Reaction time< 30
Duration of risk≤ 30
Cascadable (Y/N)No
Recommended actuatorCST 16-1
 
Mechanical data
 
Design of electrical connectionCable with connector
- Connector OUTmale connector M12, 4-pole
- Connector IN-
Cable length2
AWG-Number-
mechanical installation conditionsnot flush
Switch distance Sn8 mm
Ensured switch distance ON Sao6 mm
Ensured switch distance OFF Sar11 mm
hysteresismax. 1 mm
Repeat accuracy R R< 0,5 mm
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Protection classIP65, IP67 to IEC/EN 60529
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Overvoltage categoryIII
- Degree of pollution3
 
Electromagnetic compatibility (EMC)
 
EMC ratingto IEC 61000-6-2
Interfering radiationto IEC 61000-6-4
 
Electrical data
 
Cross circuit/short circuit recognition possible (Y/N)Yes
Voltage typeDC
Switch frequency3
Rated insulation voltage Ui32 VDC
Rated operating voltage Ue (stabilised PELV)
- Min. Rated operating voltage20.4
- Max. Rated operating voltage26.4
Operating current Ie1.1 A
Utilisation categoryDC-12: 24 V / 0,05 A
DC-13: 24 V / 0,05 A
No-load current I00,05 A
Device insulation
noticeCable length and cable section alter the voltage drop depending on the output current
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of secure semi-conductor outputs2
Max. output current at secured output0,5 A
Rated operating voltagemin. (Ue − 0,5 V)
Residual current Ir≤ 0,5 mA
Operating current Iemax. 0,5 A
Minimum operating current Im0,5 mA
Utilisation categoryDC-12: 24 V / 0,5 A
DC-13: 24 V / 0,5 A
Voltage drop Ud0,5 V
 
Electrical data - Diagnostic output
 
Number of semi-conductor outputs with signaling function0
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Multi-coloured LEDgreen, red, yellow
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor55
- Height of sensor93
- Length of sensor39.5
 
Pin assignment
 
1A1 Ue
2Y2 Safety output 2
3A2 GND
4Y1 Safety output 1
 
notice
 
Requirements for the safety monitoring module2-channel safety input, suitable for p-type sensors with NO function. The safety monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 2 ms. The safety monitoring module does not need to have a cross-wire short monitoring function.
 
Included in delivery
 
Actuators must be ordered separately.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 21.09.2019 - 17:14:08h Kasbase 3.3.0.F.64I