|  Preferred typ |
|
Ordering details |
|
Product type description | CSS 8-180-2P+D-M-ST |
Article number | 101209595 |
EAN Code | 4030661387758 |
eCl@ss | 27-27-24-01 |
|
Approval |
|
Approval | BG
USA/CAN
EAC |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508, IEC 60947-5-3 |
PL | up e |
Control category | bis 4 |
PFH | 2.5 x 10- 9 / h |
SIL | bis 3 |
Mission time | 20 Years |
Classification | PDF-M |
|
Global Properties |
|
Permanent light | CSS 180 |
Standards | IEC 61508, IEC 60947-5-3 |
Compliance with the Directives (Y/N)  | Yes |
Suitable for safety functions (Y/N) | Yes |
Function | Individual sensor or end sensor in a series, Sensor for series wiring |
Series-wiring | up to 16 components |
Length of the sensor chain | max. 200 m |
Active principle | inductive |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
- Material of the nuts | Plastic, glass-fibre reinforced thermoplastic |
- Material of the active surface | Plastic, glass-fibre reinforced thermoplastic |
Housing construction form | cylinder, thread |
Weight | 138 |
Reaction time | ≤ 30 |
Duration of risk | ≤ 30 |
Cascadable (Y/N) | No |
Recommended actuator | CST 180-1, CST 180-2 |
|
Mechanical data |
|
Design of electrical connection | connector plug M12, 8-pole |
- Connector IN/OUT | Connector M12, 8-pole |
mechanical installation conditions | not flush |
Switch distance Sn | 8 mm |
Ensured switch distance ON Sao | 7 mm |
Ensured switch distance OFF Sar | 10 mm |
hysteresis | ≤ 0,7 mm |
Repeat accuracy R R | ≤ 0,2 mm |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 55 HZ, Amplitude 1 mm |
Tightening torque for nuts | A/F 24 max. 300 Ncm |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +60 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Protection class | IP65, IP67 to IEC/EN 60529 |
Protection rating | II |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp | 0,8 kV |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electrical data |
|
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Voltage type | DC |
Supply voltage UB |
- Min. supply voltage | 20.4 V DC |
- Max. supply voltage | 26.4 V DC |
Switch frequency | 3 |
Rated insulation voltage Ui | 32 V DC |
Residual current Ir | ≤ 0,5 mA |
Operating current Ie | 1 A |
Utilisation category | DC-12: 24 V / 0,5 A DC-13: 24 V / 0,5 A |
No-load current I0 | 0,05 A |
|
Electrical data - Safety outputs |
|
Safety outputs | Y1 and Y2 |
Fuse rating | short-circuit proof, p-type |
Design of control output | PNP |
Number of secure semi-conductor outputs | 2 |
Max. output current at secured output | 0,5 A |
Rated operating voltage | 24 VDC |
Operating current Ie | 0,5 A |
Utilisation category | DC-12: 24 V / 0,5 A DC-13: 24 V / 0,5 A |
Voltage drop Ud | max. 0,5 V |
|
Electrical data - Diagnostic output |
|
Fuse rating | short-circuit proof, p-type |
Design of control output | PNP |
Number of semi-conductor outputs with signaling function | 1 |
Rated operating voltage | 24 VDC |
Operating current Ie | 0,05 A |
Utilisation category | DC-12, DC-13 |
Wiring capacitance for serial diagnostics | max. 50 nF |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
Multi-coloured LED | green, red, yellow |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Length of sensor | 92 |
- Diameter of sensor | M18 |
|
Pin assignment |
|
1 | A1 Ue |
2 | X2 Safety input 2 |
3 | A2 GND |
4 | Y1 Safety output 1 |
5 | Signalling output |
6 | X1 Safety input 1 |
7 | 2 Safety output Y2 |
8 | without function |
|
notice |
|
Requirements for the safety monitoring module | 2-channel safety input, suitable for p-type sensors with NO function. The safety monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 2 ms. The safety monitoring module does not need to have a cross-wire short monitoring function. |
|
Included in delivery |
|
Actuators must be ordered separately. |
Mounting accessories | 2 x Nuts M 18 x 1 |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
20.02.2019 -
02:50:39h Kasbase 3.3.0.F.64I |