Ordering details |
|
Product type description | AZM 161 B ST1-AS R |
Article number | 101209099 |
EAN Code | 4030661399720 |
eCl@ss | 27-27-26-03 |
|
Approval |
|
Approval | AS-i
TÜV
USA/CAN |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508 |
PL | up c |
Control category | 1 |
PFH | 1.14 x 10-6 / h |
- notice | up to max. 100.000 switching cycles/year |
SIL | up 1 |
Mission time | 20 Years |
If a fault exclusion for hazardous damage of the 1-channel mechanics is authorized and an adequate protection against tampering is ensured, suitable for use up to: |
Standards | EN ISO 13849-1, IEC 61508 |
PL | up d |
Control category | 3 |
PFH value | 1.01 x 10-7 / h |
- notice | up to max. 100.000 switching cycles/year |
SIL | up 2 |
Mission time | 20 Years |
|
Global Properties |
|
Permanent light | AZM 161 AS |
Standards | EN 50295, EN 60947-5-1, IEC 61508, EN ISO 13849-1 |
Compliance with the Directives (Y/N)  | Yes |
Number of actuating directions | 3 |
Active principle | electromechanical |
Duty cycle ED | Magnet 100 % |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Housing coating | None |
Weight | 490 |
Guard locking monitored (Y/N) | No |
Actuator monitored (Y/N) | Yes |
Response time | < 100 |
|
Mechanical data |
|
Actuating play in direction of actuation | 5.5 |
Design of electrical connection | connector plug M12, 4-pole |
connector | bottom |
Mechanical life | > 1.000.000 operations |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 HZ … 150 HZ, Amplitude 0,35 mm |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | Yes |
Emergency release (Y/N) | No |
Latching force | 30 |
Clamping force F | 2000 N |
Max. Actuating speed | 2 |
Actuating frequency | max. 1000 / h |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +60 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Relative humidity | 30 … 95 |
- non-condensing |
Protection class | IP67 to IEC/EN 60529 |
Protection rating | II  |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp | 0,8 kV |
- Rated insulation voltage Ui | 32 VDC |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electrical data |
|
Power to unlock | Yes |
Power to lock | No |
|
Electrical data - AS interface |
|
AS-i Supply voltage | 26.5 … 31.6 VDC, Protection against polarity reversal |
AS-i operating current | ≤ 250 |
AS-i Device insulation | internally short-circuit proof |
AS-i Specification |
- version | V 2.1 |
- Profile | S-7.B.F.E |
- IO-Code | 0x7 |
- ID-Code | 0xB |
- ID-Code1 | 0xF |
- ID-Code2 | 0xE |
AS-i Inputs |
- Channel 1 | Data bits DI 0/DI 1= dynamic code transmission |
- Channel 2 | Data bits DI 2/DI 3= dynamic code transmission |
AS-i Outputs |
- DO 0 | Solenoid control |
- DO 1 | not used |
- DO 2 | not used |
- DO 3 | not used |
AS-i Parameter bits |
- P0 | Actuator detected |
- P1 | Solenoid interlock locked |
- P2 | magnet voltage in tolerance range |
- P3 | error message - locking/unlocking of the solenoid interlock blocked |
AS-i input module address | 0 |
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
AS-i LED switching conditions display |
(1) yellow LED | Channel 2 / AS-i SaW Bit 2,3 |
(2) green/red LED (AS-i duo LED) | Supply voltage / Communication error / slave address = 0 or periphery error |
(3) yellow LED | Channel 1 / AS-i SaW Bit 0,1 |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Miscellaneous data |
|
Applications | sliding safety guard,
removable guard,
hinged safety guard |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 130 |
- Height of sensor | 90 |
- Length of sensor | 30 |
|
Pin assignment |
|
1 | AS-i + |
2 | Aux − (P) |
3 | AS-i − |
4 | Aux + (P) |
|
notice |
|
Interlocks with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. |
Manual release |
• For maintenance, installation, etc. |
• For manual release using M5 triangular key, available as accessory |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
19.02.2019 -
00:04:23h Kasbase 3.3.0.F.64I |