Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
 Add Product to the basket. 
SLC 420-E/R1050-14-69-RFB
• Protection class IP69K
• Safety type 4 in accordance with IEC 61496-1
• Resolution 14 mm and 30 mm
• Protection field height from 170 mm … 1450 mm

 
 
Ordering details
 
Product type descriptionSLC 420-E/R1050-14-69-RFB
Article number101207015
EAN Code4030661376677
eCl@ss27-27-27-04
 
Approval
 
Approval TÜV
USA/CAN

( under preparation)
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLup e
Control categoryup 4
PFH value7.42 x 10-9 /h
SILup 3
Mission time20 Years
 
Global Properties
 
Permanent lightSLC 420 IP 69K Sicherheits-Lichtvorhang
StandardsIEC/EN 61496-1/-2
Compliance with the Directives (Y/N) Yes
Operating resource protection classProtection class 3
Safety type in accordance with IEC 61496-14
Materials
- Material of the housingsAluminium
Weight
Beam coding (Y/N)Yes
Protection field height1050
Range of the protection field300 - 7000
Reaction time20
Wave length of the sensors880
Fade-out is possible (Y/N)Yes
Override possible (Y/N)No
reduced resolution (Y/N)No
Clock control possible (Y/N)No
Muting possible (Y/N)No
Restart block (Y/N)Yes
Master/slave functionNo
Cascadable (Y/N)No
Monitoring function of downstream devices (Y/N)Yes
Recommended safety-monitoring moduleSRB301ST
SCR 211
 
Mechanical data
 
Detection ability for test bodies14
Number of beams104
Design of electrical connectionConnector
- Wiring of the transmittercable with connector M12, 4-pole
- Wiring of the receivercable with connector M12, 8-pole
Cable length5
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−10
- Max. environmental temperature+50
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+70
Protection classIP69K to IEC/EN 60529
 
Electrical data
 
Design of output switching element OSSDPNP
Power consumption
- Power consumption Transmitter4
- Power consumption Receiver8
Voltage typeDC
Switching voltage of the OSSD in high state24 V ± 20%
 
Outputs
 
Max. output current at secured output500
 
Electrical data - Safety outputs
 
Number of secure semi-conductor outputs2
Number of secure outputs with contact0
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- Status and diagnosticsYes
- 7-segment display
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Height of sensor1147
- Diameter of sensor60
 
notice
 
In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.
 
Included in delivery
 
Delivery scope of disposable systemTransmitter + receiver, Mounting angle

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 17.06.2019 - 05:17:09h Kasbase 3.3.0.F.64I