Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Safety sensors  ->  CSS 30S  ->  CSS 11-30S-SD-M-ST
• Stainless steel enclosure
• Max. 31 sensors can be wired in series.
• Connector M12, 8-pole
• Ø M30
• High repeat accuracy of the switching points
• Max. length of the sensor chain 200 m
• 2 short-circuit proof PNP safety outputs
• Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

• serial diagnostic output

 
Preferred typ
 
Ordering details
 
Product type descriptionCSS 11-30S-SD-M-ST
Article number101204613
EAN Code4030661381657
eCl@ss27-27-24-01
 
Approval
 
Approval TÜV
USA/CAN
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLup e
Control categorybis 4
PFH3.6 x 10 -9/h
SILbis 3
Mission time20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightCSS 30S
StandardsIEC 60947-5-3, IEC 61508
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
FunctionSensor for series wiring
Series-wiringup to 31 components
Length of the sensor chainmax. 200 m
Active principleinductive
Materials
- Material of the housingsStainless steel
Housing construction formcylinder, thread
Weight248
Diagnostic output (Y/N)Yes
Reaction time< 60
Duration of risk< 60
Cascadable (Y/N)Yes
Recommended actuatorCST 30S-1
 
Mechanical data
 
mechanical installation conditionsnot flush
Actuating planesActuation from top
Active areafront
Switch distance Sn11 mm
Ensured switch distance ON Sao8 mm
Ensured switch distance OFF Sar15 mm
hysteresis< 2 mm
Repeat accuracy R R< 1 mm
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+65
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Protection classIP65, IP67 to IEC/EN 60529
IP69K to DIN 40050-9
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Overvoltage categoryIII
- Degree of pollution3
 
Electromagnetic compatibility (EMC)
 
EMC ratingto IEC 61000-6-2
Interfering radiationto IEC 61000-6-4
 
Electrical data
 
Cross circuit/short circuit recognition possible (Y/N)Yes
Voltage typeDC
Switch frequency3
Rated insulation voltage Ui32 VAC/DC
Rated operating voltage Ue (stabilised PELV)
- Min. Rated operating voltage20.4 VDC
- Max. Rated operating voltage26.4 VDC
Operating current Ie0,6 A
No-load current I00,1 A
Required rated short-circuit current100 A
Device insulation (Circuit breaker)2 A
noticeThe cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of secure semi-conductor outputs2
Max. output current at secured output0,25 A
Rated operating voltagemin. (Ue − 1 V)
Residual current Ir< 0,5 mA
Operating current Iemax. 0,25 A
Minimum operating current Im0,5 mA
Utilisation categoryDC-12: 24 V / 0,25 A
DC-13: 24 V / 0,25 A
Voltage drop Ud< 1 V
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)Yes
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of semi-conductor outputs with signaling function1
Rated operating voltagemin. (Ue − 5 V)
Operating current Iemax. 0,05 A
Voltage drop Ud< 5 V
Utilisation categoryDC-12: 24 V / 0,05 A
DC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnosticsmax. 50 nF
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s2
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Length of sensor99.5
- Diameter of sensorM30
 
Pin assignment
 
1 - A1 Ue(1)
2 - X1 Safety input 1(2)
3 - A2 GND(3)
4 - Y1 Safety output 1(4)
5 - SD serial diagnostic output(5)
6 - X2 Safety input 2(6)
7 - Y2 Safety output 2(7)
8 - IN serial diagnostic input(8)
 
notice
 
Requirements for the safety monitoring moduleThe safety monitoring module must tolerate internal functional tests of the safety outputs for 250 μs –1500 μs.
The 250 μs switch-off time of the safety sensor additionally will be extended depending on the cable length and the capacity of the cable used. Typically, a switch-off time of 500 μs is reached with a 100 m connecting cable.
 
Included in delivery
 
Actuators must be ordered separately.
Mounting accessories Nuts M 18 x 12 piece

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 19.02.2019 - 11:53:38h Kasbase 3.3.0.F.64I