Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Safety sensors  ->  CSS 30S  ->  CSS 11-30S-D-M-ST
• Stainless steel enclosure
• Max. 31 sensors can be wired in series.
• Connector M12, 8-pole
• Ø M30
• High repeat accuracy of the switching points
• Max. length of the sensor chain 200 m
• 2 short-circuit proof PNP safety outputs
• Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet


 
Preferred typ
 
Ordering details
 
Product type descriptionCSS 11-30S-D-M-ST
Article number101204612
EAN Code4030661381664
eCl@ss27-27-24-01
 
Approval
 
Approval TÜV
USA/CAN
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLup e
Control categorybis 4
PFH3.6 x 10 -9/h
SILbis 3
Mission time20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightCSS 30S
StandardsIEC 60947-5-3, IEC 61508
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
FunctionSensor for series wiring
Series-wiringup to 31 components
Length of the sensor chainmax. 200 m
Active principleinductive
Materials
- Material of the housingsStainless steel
Housing construction formcylinder, thread
Weight245
Diagnostic output (Y/N)Yes
Reaction time< 60
Duration of risk< 60
Cascadable (Y/N)Yes
Recommended actuatorCST 30S-1
 
Mechanical data
 
mechanical installation conditionsnot flush
Actuating planesActuation from top
Active areafront
Switch distance Sn11 mm
Ensured switch distance ON Sao8 mm
Ensured switch distance OFF Sar15 mm
hysteresis< 2 mm
Repeat accuracy R R< 1 mm
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+65
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Protection classIP65, IP67 to IEC/EN 60529
IP69K to DIN 40050-9
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Overvoltage categoryIII
- Degree of pollution3
 
Electromagnetic compatibility (EMC)
 
EMC ratingto IEC 61000-6-2
Interfering radiationto IEC 61000-6-4
 
Electrical data
 
Cross circuit/short circuit recognition possible (Y/N)Yes
Voltage typeDC
Switch frequency3
Rated insulation voltage Ui32 VAC/DC
Rated operating voltage Ue (stabilised PELV)
- Min. Rated operating voltage20.4 VDC
- Max. Rated operating voltage26.4 VDC
Operating current Ie0,6 A
No-load current I00,1 A
Required rated short-circuit current100 A
Device insulation (Circuit breaker)2 A
noticeThe cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of secure semi-conductor outputs2
Max. output current at secured output0,25 A
Rated operating voltagemin. (Ue − 1 V)
Residual current Ir< 0,5 mA
Operating current Iemax. 0,25 A
Minimum operating current Im0,5 mA
Utilisation categoryDC-12: 24 V / 0,25 A
DC-13: 24 V / 0,25 A
Voltage drop Ud< 1 V
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)No
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of semi-conductor outputs with signaling function1
Rated operating voltagemin. (Ue − 5 V)
Operating current Iemax. 0,05 A
Voltage drop Ud< 5 V
Utilisation categoryDC-12: 24 V / 0,05 A
DC-13: 24 V / 0,05 A
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s2
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Length of sensor99.5
- Diameter of sensorM30
 
Pin assignment
 
1 - A1 Ue(1)
2 - X1 Safety input 1(2)
3 - A2 GND(3)
4 - Y1 Safety output 1(4)
5 - OUT Diagnostic output(5)
6 - X2 Safety input 2(6)
7 - Y2 Safety output 2(7)
8 - IN without function(8)
 
notice
 
Requirements for the safety monitoring moduleThe safety monitoring module must tolerate internal functional tests of the safety outputs for 250 μs –1500 μs.
The 250 μs switch-off time of the safety sensor additionally will be extended depending on the cable length and the capacity of the cable used. Typically, a switch-off time of 500 μs is reached with a 100 m connecting cable.
 
Included in delivery
 
Actuators must be ordered separately.
Mounting accessories Nuts M 18 x 12 piece

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.02.2019 - 21:53:25h Kasbase 3.3.0.F.64I