Solenoid interlock  ->  MZM 100  ->  Archive  ->  MZM 100 B ST-SD2PR-A
 Add Product to the basket. 
MZM 100 B ST-SD2PR-A
• Actuator monitored
• Automatic latching
• Solenoid interlocks (for the protection of man) with innovating and unique operating principle
• 40 mm x 179 mm x 40 mm
• Electronic contact-free, coded system
• Thermoplastic enclosure
• Max. length of the sensor chain 200 m
• 3 LEDs to show operating conditions
• Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
• Intelligent diagnosis
• Self-monitoring series-wiring of 31 sensors
• Patented
• Connector M23, 8+1-pole
• Power to lock
• serial diagnostic output

 
 
Ordering details
 
NOTICE: Not available! (Replacement: MZM 100 B ST2-SD2PRE-A)
Product type descriptionMZM 100 B ST-SD2PR-A
Article number101204269
EAN Code
eCl@ss27-27-26-03
 
Approval
 
Approval USA/CAN
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3, EN 60947-5-1
PLe
Control categoryup 4
PFH3.5 x 10-9/h
SILup 3
Mission time20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightMZM 100
StandardsIEC 61508, EN ISO 13849-1, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Protection ratingIII
Series-wiringup to 31 components
Length of the sensor chainmax. 200 m
− without detriment to the category to EN ISO 13849-1
Active principleinductive
Duty cycle ED100 %
CodingUniversal coding
low
Duty cycle ED100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight625
Guard locking monitored (Y/N)No
Actuator monitored (Y/N)Yes
Idle assignable pushbutton and LED (Y/N)No
Reaction time< 150
Duration of risk< 150
Time to readiness< 4000
Recommended actuatorMZM 100-B1.1
 
Mechanical data
 
Design of electrical connectionConnector M23, 8+1-pole
Mechanical life≥ 1.000.000 operations
notice - Mechanical lifeoperations for guards ≤ 5 kg;
actuating speed
≤ 0,5 m/s
restistance to shock30 g / 11 ms
Resistance to vibration10 … 150 HZ, Amplitude 0,35 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)No
Emergency release (Y/N)No
Latching (Y/N)Yes
Latching force30
Clamping force F
- typically750 N
- guaranteed500
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30… 95
- non-condensing
- non-icing
Protection classIP67 to IEC/EN 60529
Protection ratingIII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Power to unlockNo
Power to lockYes
Supply voltage UB (stabilised PELV)
- Min. supply voltage20.4 V DC
- Max. supply voltage26.4 V DC
Switch frequency1
Rated insulation voltage Ui32 V DC
Operating current Ie1 A
Utilisation categoryDC-13
No-load current I0max. 0,5 A
Required rated short-circuit current100 A
Device insulation≤ 2 A
- to UL 508; depending on the number of devices and loads (Y1, Y2 and OUT)
noticeCable length and cable section alter the voltage drop depending on the output current
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
Rated operating voltage Ue- 3 V … 5 V (Low)
15 V … 30 V (High)
Operating current Ie> 2 mA / 24 V
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof, p-type
Rated operating voltage0 V … 4 V under Supply voltage UB
Residual current Ir≤ 0,5 mA
Operating current Ie0,25 A
Utilisation categoryDC-12, DC-13
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)Yes
Wiring capacitance for serial diagnostics50
diagnostic signalsto SD-interface
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!
 
Electrical data - Solenoid control IN
 
Control commandInterlocking the solenoid interlock
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltage UBgreen LED
- switching conditionyellow LED
- Error functional defectred LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor179
- Length of sensor40
 
Pin assignment
 
1A1 Supply voltage UB
2X1 Safety input 1
3A2 GND
4Y1 Safety output 1
5OUT serial diagnostic output
6X2 Safety input 2
7Y2 Safety output 2
8IN serial diagnostic input
9without function
 
notice
 
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required.
 
Included in delivery
 
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.04.2019 - 08:33:57h Kasbase 3.3.0.F.64I