Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
 Add Product to the basket. 
MZM 100 B ST-AS REAP
• Solenoid interlock
• Thermoplastic enclosure
• Integrated AS-Interface
• 40 mm x 179 mm x 40 mm
• Solenoid interlocks (for the protection of man) with innovating and unique operating principle
• Electronic contact-free, coded system
• 3 LEDs to show operating conditions
• Automatic latching
• Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
• Intelligent diagnosis
• Power to lock
• Actuator monitored

 
Preferred typ
 
Ordering details
 
Product type descriptionMZM 100 B ST-AS REAP
Article number101198705
EAN Code4030661370767
eCl@ss27-27-26-03
 
Approval
 
Approval USA/CAN
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLup e
Control categoryup 4
PFH≤ 5 x 10-9/h
SILup 3
Mission time20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightMZM 100 AS
StandardsEN 60947-5-1, IEC 61508, EN 50295, IEC 60947-5-3, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Protection ratingIII
Active principleinductive
CodingUniversal coding
low
Duty cycle ED100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight605
Guard locking monitored (Y/N)No
Actuator monitored (Y/N)Yes
Response time< 150 ms
Duration of risk< 150 ms
Time to readiness< 4000
Recommended actuatorMZM 100-B1.1
 
Mechanical data
 
Design of electrical connectionconnector plug M12, 4-pole
Mechanical life≥ 1.000.000 operations
notice - Mechanical lifeoperations for guards ≤ 5 kg;
actuating speed
≤ 0,5 m/s
restistance to shock30 g / 11 ms
Resistance to vibration10 … 150 HZ, Amplitude 0,35 mm
Latching (Y/N)Yes
electrically adjustable latching force30 … 100
Permanent magnet-
Clamping force F500 N
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30… 95
- non-condensing
- non-icing
Protection classIP67 to IEC/EN 60529
Protection ratingIII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Rated insulation voltage Ui32 VDC
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Power to lockYes
 
Electrical data - AS interface
 
AS-i Supply voltage26.5 … 31.6 VDC, Protection against polarity reversal
AS-i operating current≤ 100
AS-i Device insulationinternally short-circuit proof
AS-i Specification
- versionV 2.1
- ProfileS-7.B.F.E
- IO-Code0x7
- ID-Code0xB
- ID-Code10xF
- ID-Code20xE
AS-i Inputs
- Channel 1Data bits DI 0/DI 1= dynamic code transmission
- Channel 2Data bits DI 2/DI 3= dynamic code transmission
AS-i Outputs
- DO 0Solenoid control
- DO 1for the variable setting of the latching force
- DO 2for the variable setting of the latching force
- DO 3for the variable setting of the latching force
AS-i Parameter bits
- P0Actuator in
- P1Solenoid interlock locked
- P2Auxiliary voltage in
- P3device error (Error detected)
AS-i input module address0
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device
 
Electrical data - Auxiliary voltage (Aux)
 
Supply voltage UB24 VDC (−15 % / +10 %) stabilised PELV
Operating current≤ 600
Device insulation≤ 4 A (if used in accordance with UL 508)
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
AS-i LED switching conditions display
(1) green/red LED (AS-i duo LED)Supply voltage / Communication error / slave address = 0
(2) yellow LEDDevice status
(3) red LEDdevice error
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor179
- Length of sensor40
 
Pin assignment
 
1AS-i +
2Aux − (P)
3AS-i −
4Aux + (P)
 
notice
 
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required.
Interlocks with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened.
 
Included in delivery
 
Actuators must be ordered separately.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 18.06.2019 - 02:50:32h Kasbase 3.3.0.F.64I