• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 2 safety contacts, STOP 0; 1 safety contact, STOP 1
• 1 Signalling output
• Control category 4 to EN ISO 13849-1

 
 
Ordering details
 
Product type descriptionSCR 211
Article number101196815
EAN Code4030661365008
eCl@ss27-37-19-01
 
Approval
 
ApprovalUSA/CAN
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, EN 60947-5-1
Control categoryup 4 (STOP 0)
up 3 (STOP 1)
PLup e (STOP 0)
up d (STOP 1)
DC99% (STOP 0)
> 60% (STOP 1)
CCF> 65 points
PFH value5 x 10-9/h
- noticeup to max. 36.500 switching cycles/year
SILup 3 (STOP 0)
up 2 (STOP 1)
Mission time20 Years
 
Global Properties
 
Permanent lightSCR 211
StandardsIEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-78
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, ventilated
- Material of the contactsAgSn0, Ag-Ni, self-cleaning, positive action
Weight255
Start conditionsAutomatic or Start button
Start input (Y/N)Yes
Feedback circuit (Y/N)Yes
Start-up test (Y/N)No
Reset after disconnection of supply voltage (Y/N)Yes
Automatic reset function (Y/N)Yes
Reset with edge detection (Y/N)Yes
Pull-in delay
- ON delay with automatic start≤ 40 ms
Drop-out delay
- Drop-out delay in case of emergency stop≤ 50 ms
 
Mechanical data
 
Connection typeScrew connection, plug-in
Cable section
- Min. Cable section0,25
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)Yes
Mechanical life10.000.000 operations
Electrical lifetimeDerating curve available on request
restistance to shock10 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm, ± 15 %
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm, ± 15 %
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+45 °C
Storage and transport temperature
- Min. Storage and transport temperature−40 °C
- Max. Storage and transport temperature+85 °C
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4 kV
- Overvoltage categoryII To VDE 0110
- Degree of pollution2 To VDE 0110
 
Electromagnetic compatibility (EMC)
 
EMC ratingconforming to EMC Directive
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls20.4
- Max. rated DC voltage for controls28.8
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz20.4
- Max. rated AC voltage for controls, 50 Hz26.4
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz20.4
- Max. rated AC voltage for controls, 60 Hz26.4
Contact resistancemax. 100 mΩ
Power consumption5.1 W; 10 VA; plus signalling output
Type of actuationAC/DC
Rated operating voltage Ue24 VAC/DC
Frequency range50 / 60 HZ
Electronic protection (Y/N)Yes
Fuse rating for the operating voltageInternal electronic trip, tripping current > 1.0 A, Reset after disconnection of supply voltage
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)optional
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)Yes
Number of shutters0 piece
Number of openers2 piece
Cable length1500 m with 1.5 mm²;
2500 m with 2.5 mm² (for Rated voltage)
Conduction resistancemax. 40 Ω
 
Outputs
 
Stop category0 / 1
- Stop category 013-14, 23-24:
AC-15: 230 V / 1,5 A,
DC-13: 24 V / 1,2 A
- Stop category 137-38:
AC-15: 230 V / 3 A,
DC-13: 24 V / 2 A
Number of safety contacts3 piece
Number of auxiliary contacts0 piece
Number of signalling outputs1 piece
Fuse rating
Switching capacity
- Switching capacity of the safety contacts(STOP 0) max. 250 VAC, 4 A ohmic (inductive in case of appropriate protective wiring)
(STOP 1) max. 250 VAC, 4 A ohmic (inductive in case of appropriate protective wiring)
- Switching capacity of the signaling/diagnostic outputs24 VDC, 100 mA
Fuse rating
- Protection of the safety contacts(STOP 0) 4 A slow blow
(STOP 1) 4 A slow blow
- Fuse rating for the signaling/diagnostic outputsInternal electronic trip, tripping current > 0,1 A
Utilisation category To EN 60947-5-1
Number of undelayed semi-conductor outputs with signaling function1 piece
Number of undelayed outputs with signaling function (with contact)0 piece
Number of delayed semi-conductor outputs with signaling function.0 piece
Number of delayed outputs with signalling function (with contact).0 piece
Number of secure undelayed semi-conductor outputs with signaling function0 piece
Number of secure, undelayed outputs with signaling function, with contact.2 piece
Number of secure, delayed semi-conductor outputs with signaling function0 piece
Number of secure, delayed outputs with signaling function (with contact).1 piece
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s4
LED switching conditions display
- The integrated LEDs indicate the following operating states.
- Position relay K2
- Position relay K1
- Position relay K3/K4
- Internal operating voltage Ui
 
Miscellaneous data
 
Applications Emergency-Stop button
Pull-wire emergency stop switches
Guard system
Safety light curtain
 
Dimensions
 
Dimensions
- Width22.5 mm
- Height100 mm
- Depth121 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R) and feedback circuit (H2).
The control system recognises wire-breakage and earth faults in the monitoring circuit.
Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts.
Control category 3 to EN ISO 13849-1
Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X3. If the feedback circuit is not required, establish a bridge
The wiring diagram is shown with guard doors closed and in de-energised condition.