Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 2 safety contacts, STOP 0; 2 safety contacts, STOP 1

 
Preferred typ
 
Ordering details
 
Product type descriptionSRB220XV2 / V.2
Article number101195578
EAN Code4250116202188
Replaced article number 101188429
eCl@ss27-37-19-01
 
Approval
 
Approval BG
USA/CAN
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, EN 60947-5-1
PLup e (STOP 0)
bis d (STOP 1)
Control categoryup 4 (STOP 0)
up 3 (STOP 1)
DC99% (STOP 0)
> 60% (STOP 1)
CCF> 65 points
PFH value≤ 2,0 x 10-8/h (STOP 0)
≤ 2,0 x 10
-7/h (STOP 1)
SILup 3 (STOP 0)
up 2 (STOP 1)
Mission time20 Years
- noticeThe PFH value is applicable for the combinations listed in the table for contact load (K) (current through enabling paths) and switching cycle number (n-op/y).
In case of 365 operating days per year and a 24-hour operation, this results in the specified switching cycle times (t-cycle) for the relay contacts.
Diverging applications on request.
 
Global Properties
 
Permanent lightSRB220XV2 / V.2
StandardsIEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-78
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, ventilated
- Material of the contactsAgSn0, Ag-Ni, self-cleaning, positive action
Weight475
Start conditionsAutomatic or Start button (Optional monitored)
Start input (Y/N)Yes
Feedback circuit (Y/N)Yes
Start-up test (Y/N)No
Reset after disconnection of supply voltage (Y/N)No
Automatic reset function (Y/N)Yes
Reset with edge detection (Y/N)Yes
Pull-in delay
- ON delay with reset buttontyp. 20 ms
Drop-out delay
- Drop-out delay in case of power failuretyp. 50 ms
- Drop-out delay in case of emergency stop≤ 25 ms
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Min. Cable section0,25
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)No
Mechanical life10.000.000 operations
Electrical lifetimeDerating curve available on request
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm, ± 15 %
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+60 °C
Storage and transport temperature
- Min. Storage and transport temperature−40 °C
- Max. Storage and transport temperature+85 °C
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4 kV
- Overvoltage categoryII To VDE 0110
- Degree of pollution2 To VDE 0110
 
Electromagnetic compatibility (EMC)
 
EMC ratingconforming to EMC Directive
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls20.4
- Max. rated DC voltage for controls28.8
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz20.4
- Max. rated AC voltage for controls, 50 Hz26.4
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz20.4
- Max. rated AC voltage for controls, 60 Hz26.4
Contact resistancemax. 100 mΩ
Power consumptionmax. 2.6 W; 5.4 VA
Type of actuationAC/DC
Rated operating voltage Ue24 VDC −15% / +20%, residual ripple max. 10 %
24 VAC −15% / +10%
Frequency range50 / 60 HZ
Electronic protection (Y/N)Yes
Fuse rating for the operating voltageInternal electronic trip, tripping current > 1.0 A, Reset after disconnection of supply voltage
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)optional
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)Yes
Number of shutters0 piece
Number of openers2 piece
Cable length1500 m with 1.5 mm²;
2500 m with 2.5 mm²
Conduction resistancemax. 40 Ω
 
Outputs
 
Stop category0 / 1
Number of safety contacts4 piece
Number of auxiliary contacts0 piece
Number of signalling outputs0 piece
Switching capacity
- Switching capacity of the safety contactsmax. 250 V, 8 A ohmic (inductive in case of appropriate protective wiring)
Fuse rating
- Protection of the safety contacts8 A slow blow
Utilisation category To EN 60947-5-1
- Stop category 013-14, 23-24:
AC-15: 230 V / 6 A
DC-13: 24 V / 6 A
- Stop category 137/38, 47 - 48:
AC-15: 230 V / 3 A
DC-13: 24 V / 2 A
Number of undelayed semi-conductor outputs with signaling function0 piece
Number of undelayed outputs with signaling function (with contact)0 piece
Number of delayed semi-conductor outputs with signaling function.0 piece
Number of delayed outputs with signalling function (with contact).0 piece
Number of secure undelayed semi-conductor outputs with signaling function0 piece
Number of secure, undelayed outputs with signaling function, with contact.2 piece
Number of secure, delayed semi-conductor outputs with signaling function0 piece
Number of secure, delayed outputs with signaling function (with contact).2 piece
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s5
LED switching conditions display
- The integrated LEDs indicate the following operating states.
- Position relay K1
- Position relay K4
- Position relay K3
- Position relay K2
- Supply voltage
- Internal operating voltage Ui
 
Miscellaneous data
 
Applications Emergency-Stop button
Pull-wire emergency stop switches
Guard system
Safety light curtain
 
Dimensions
 
Dimensions
- Width45 mm
- Height100 mm
- Depth121 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
2 channel control shown for a guard-door monitor with two contacts, of which at least one contact has positive break, with external reset button (R).
Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts.
(H2) = Feedback circuit
The control recognises cross-short, cable break and earth leakages in the monitoring circuit.
The time-delayed safety outputs 37-38 and 47-48 meet the requirements of STOP category 1 to EN 60204-1. The non-delayed safety outputs meet the requirements of STOP category 0 to EN 60204-1.
Setting of the drop-out delay time is carried out by means of a DIP switch from the front of the enclosure.
The wiring diagram is shown with guard doors closed and in de-energised condition.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 19.09.2019 - 19:28:17h Kasbase 3.3.0.F.64I