Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
• Thermoplastic enclosure • Long life • no mechanical wear • 88 mm x 25 mm x 13 mm • Concealed mounting possible • Insensitive to transverse misalignment • Insensitive to soiling
B10d Normally-closed contact/Normally open contact (NC/NO)
25.000.000
- notice
at max. 20% contact load
Mission time
20 Years
notice
Global Properties
Permanent light
BNS 36
Standards
IEC 60947-5-3, BG-GS-ET-14
Compliance with the Directives (Y/N)
Yes
Category safety pursuant to EN ISO 13849-1
up 4 - Only in combination with safety monitoring module
Materials
- Material of the housings
Plastic, glass-fibre reinforced thermoplastic
- Material of the cable mantle
PVC
Weight
65
Coding available (Y/N)
Yes
Monitoring function of downstream devices (Y/N)
No
Prerequisite evaluation unit
Recommended safety-monitoring module
Recommended actuator
BPS 36-1, BPS 36-2
Mechanical data
Design of electrical connection
Cable
Cable length
1
Conductors
4 x 0,25
AWG-Number
30
mechanical installation conditions
quasi-flush
Active area
Ensured switch distance ON Sao
7 mm
Ensured switch distance OFF Sar
17 mm
notice
Axial misalignment The safety sensor and the actuator tolerate a horizontal and vertical misalignment to each other. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor is active in the tolerance range.
Type of actuation
Magnet
Direction of motion
head-on with regard to the active surface
restistance to shock
30 g / 11 ms
Resistance to vibration
10 … 55 HZ, Amplitude 1 mm
Door hinge
left
Ambient conditions
Ambient temperature
- Min. environmental temperature
−25 °C
- Max. environmental temperature
+70 °C
Storage and transport temperature
- Min. Storage and transport temperature
−25 °C
- Max. Storage and transport temperature
+70 °C
Protection class
IP67
Electrical data
Integrated Safety monitoring module available (Y/N)
No
Cross circuit/short circuit recognition possible (Y/N)
Yes
Voltage type
VDC
Switch frequency
max. 5 HZ
Switching voltage
max. 75 VDC
Switching current
max. 400 mA
Switching capacity
max. 10 W
Outputs
Design of control output
Number of shutters
1
Number of openers
1
Design of output signal switching device
Electrical data - Safety outputs
Number of secure semi-conductor outputs
0
Number of secure outputs with contact
2
Electrical data - Diagnostic output
Number of semi-conductor outputs with signaling function
0
Number of outputs with signaling function that already have a contact
0
LED switching conditions display
LED switching conditions display (Y/N)
No
ATEX
Explosion protection categories for gases
None
Explosion protected category for dusts
None
Dimensions
Dimensions of the sensor
- Width of sensor
88 mm
- Height of sensor
25 mm
- Length of sensor
13 mm
notice
Contact symbols shown for the closed condition of the guard device.
The contact configuration for versions with or without LED is identical.
Included in delivery
Actuators must be ordered separately.
Diagram
Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
18.02.2019 -
23:25:27h Kasbase 3.3.0.F.64I