Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Solenoid interlock  ->  AZM 161  ->  AZM 161ST-11/12KA-024
 Add Product to the basket. 
AZM 161ST-11/12KA-024
• Thermoplastic enclosure
• Double-insulated
• Interlock with protection against incorrect locking.
• 130 mm x 90 mm x 30 mm
• 6 Contacts
• Long life
• Large wiring compartment
• Manual release
• cable entries 2 M 16 x 1.5
• 2 Connector M12, 4- and 8-poles

 
 
Ordering details
 
Product type descriptionAZM 161ST-11/12KA-024
Article number101192436
EAN Code4030661352367
eCl@ss27-27-26-03
 
Approval
 
Approval BG
USA/CAN
CCC
EAC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)2.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightAZM 161
StandardsEN 60947-5-1, BG-GS-ET-19
Compliance with the Directives (Y/N) Yes
Number of actuating directions3
Active principleelectromechanical
Duty cycle EDMagnet 100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Material of the contactsSilver
Housing coatingNone
 
Mechanical data
 
Actuating play in direction of actuation5.5 mm
Design of electrical connectionConnector M12
Plug-in connectors required2
Mechanical life> 1.000.000 operations
Emergency unlocking device (Y/N)No
Manual release (Y/N)Yes
Emergency release (Y/N)No
Latching force5
Positive break force20
positive break travel10
Clamping force F2000 N
Max. Actuating speed2 m/s
Actuating frequencymax. 1000 / h
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+60 °C
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts2
Number of safety contacts3
Power to unlockNo
Power to lockYes
Rated control voltage Us24 VAC/DC
Power consumptionmax. 10 W
Power consumptionmax. 10 W
Rated impulse withstand voltage UimpConnector 4-pole - 2.5 kV
Connector 8-pole - 0,8 kV
Rated insulation voltage UiConnector 4-pole - 250 V
Connector 8-pole - 60 V
Thermal test current ItheConnector 4-pole - 4 A
Connector 8-pole - 2 A
Utilisation categoryConnector 4-pole - AC-15: 230 V / 4 A
Connector 8-pole - DC-13: 60 V / 2 A
Required rated short-circuit current1000 A
Max. fuse rating6 A gG D-fuse To DIN EN 60269-1
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Miscellaneous data
 
Applications sliding safety guard,
removable guard,
hinged safety guard
 
Dimensions
 
Dimensions of the sensor
- Width of sensor130 mm
- Height of sensor90 mm
- Length of sensor30 mm
 
notice
 
Manual release
• For maintenance, installation, etc.
• For manual release using M5 triangular key, available as accessory
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 26.05.2019 - 07:02:37h Kasbase 3.3.0.F.64I