Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Solenoid interlock  ->  EX-AZM 161  ->  EX-AZM 161SK-12/12K-024-3D
 Add Product to the basket. 
EX-AZM 161SK-12/12K-024-3D
• Screw connection
• 6 Contacts
• 130 mm x 114 mm x 30 mm
• Large wiring compartment
• Clamping force 2000N
• Manual release
• Interlock with protection against incorrect locking.
• High holding force
• Long life
• Double-insulated
• Ex-certified screwed cable gland
• Ex certified
• 4 cable entries M 16 x 1.5

 
 
Ordering details
 
Product type descriptionEX-AZM 161SK-12/12K-024-3D
Article number101191458
EAN Code4030661350639
eCl@ss27-27-26-03
 
Approval
 
ApprovalATEX
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)2.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightEX-AZM 161
StandardsEN 60079-0, EN 60079-31, EN 60947-5-1, BG-GS-ET-19
Compliance with the Directives (Y/N) Yes
Number of actuating directions3
Active principleelectromechanical
Duty cycle EDMagnet 100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Material of the contactsSilver
Housing coatingNone
Weight470
 
Mechanical data
 
Actuating play in direction of actuation5.5
Design of electrical connectionScrew connection
Cable cross-section of the cable glands
- Min. Cable cross-section of the cable glandsØ 5
- Max. Cable cross-section of the cable glandsØ 10
Cable section
- Min. Cable section1 x 0,75
- Max. Cable section1 x 1.5
Mechanical life> 1.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Emergency unlocking device (Y/N)No
Manual release (Y/N)Yes
Emergency release (Y/N)No
Latching force5
Positive break force20
positive break travel10
Clamping force F2000 N
Impact energy1 J
Max. Actuating speed1
Actuating frequencymax. 1000 / h
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−10
- Max. environmental temperature+50
Protection classIP67
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts2
Number of safety contacts4
Power to unlockYes
Power to lockNo
Rated control voltage Us24 VAC/DC
Power consumptionmax. 10 W
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui250 V
Thermal test current Ithe5 A
Utilisation categoryAC-15: 230 V / 4 A, DC-13: 24 V / 2,5 A
Max. fuse rating6 A gG D-fuse
 
ATEX
 
EX-markingEX II 3D Ex tc IIIC T80°C Dc X
Explosion protection categories for gasesNone
Explosion protection Zones for gasesNone
Explosion protected category for dusts3D
Explosion protection Zones for dusts22
 
Dimensions
 
Dimensions of the sensor
- Width of sensor130
- Height of sensor114
- Length of sensor30
 
notice
 
Manual release
• For maintenance, installation, etc.
• For manual release using M5 triangular key, available as accessory
 
Included in delivery
 
Actuators must be ordered separately.
Including Ex-certified screwed cable gland and screw plug
 
Keywords
 
KeywordsEx, EEx, ATEX, Ex AZM161, Ex AZM161, AZM 161 Ex, AZM161ex, AZM161ex, ATEX AZM161
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 19.05.2019 - 15:08:31h Kasbase 3.3.0.F.64I