Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Safety switch with separate actuator
• Thermoplastic enclosure
• Integrated AS-Interface
• 40 mm x 220 mm x 50 mm
• 3 LEDs to show operating conditions
• Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
• Intelligent diagnosis
• With door detection sensor T
• Protection class IP67

 
Preferred typ
 
Ordering details
 
Product type descriptionAZ 200ST-T-AS
Article number101190950
EAN Code4030661356440
eCl@ss27-27-26-02
 
Approval
 
Approval USA/CAN
AS-i
TÜV
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLup e
Control categoryup 4
PFH4.0 x 10-9/h
SIL3
Mission time20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightAZ 200 AS
StandardsIEC 60947-5-3, IEC 61508, EN ISO 13849-1, EN 60947-5-1, EN 50295
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Active principleNon-contact
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight335
Actuator monitored (Y/N)Yes
Response time< 60
Duration of risk> 120
Time to readiness4000
 
Mechanical data
 
Design of electrical connectionconnector plug M12, 4-pole
Mechanical life≥ 1.000.000 operations
Switch distance Sn6.5 mm
Ensured switch distance ON Sao4 mm
Ensured switch distance OFF Sar30 mm
hysteresismax. 1.5
Repeat accuracy R R< 0,5 mm
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)No
Emergency release (Y/N)No
Latching force30
Max. Actuating speed≤ 0,2
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30… 95
- non-condensing
Protection classIP67 to IEC/EN 60529
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Rated insulation voltage Ui32 VDC
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data - AS interface
 
AS-i Supply voltage26.5 … 31.6 VDC, Protection against polarity reversal
AS-i operating current≤ 50
AS-i Device insulationinternally short-circuit proof
AS-i Specification
- versionV 2.1
- ProfileS-0.B.F.E
- IO-Code0x0
- ID-Code0xB
- ID-Code10xF
- ID-Code20xE
AS-i Inputs
- Channel 1Data bits DI 0/DI 1= dynamic code transmission
- Channel 2Data bits DI 2/DI 3= dynamic code transmission
AS-i OutputsDO 0 … DO 3 not used
AS-i Parameter bits
- P0Safety guard and actuator detected
- P1Safety release
- P2static 0
- P3Error
AS-i input module address0
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
AS-i LED switching conditions display
(1) green/red LED (AS-i duo LED)Supply voltage / Communication error / slave address = 0
(2) red LEDdevice error
(3) yellow LEDDevice status
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor220
- Length of sensor50
 
Pin assignment
 
1AS-i +
2None (≤ 30 VDC)
3AS-i -
4None (≤ 30 VDC)
 
Included in delivery
 
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 17.02.2019 - 21:30:48h Kasbase 3.3.0.F.64I