Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Solenoid interlock
• Thermoplastic enclosure
• High holding force 2000
• 40 mm x 244 mm x 50 mm
• Interlock with protection against incorrect locking.
• Double-insulated
• Long life
• Integrated AS-Interface
• Solenoid supply 24 VDC (Aux)
• Guard locking monitored

 
Preferred typ
 
Ordering details
 
Product type descriptionAZM 200ST-T-AS AP
Article number101190948
EAN Code4030661356433
eCl@ss27-27-26-03
 
Approval
 
Approval AS-i
TÜV
USA/CAN
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLup e
Control category4
PFH4 x 10-9 / h
SILup 3
Mission time20 Years
ClassificationPDF-M
 
Global Properties
 
Permanent lightAZM 200 AS
StandardsEN 50295, EN 60947-5-1, IEC 61508, EN ISO 13849-1, IEC 60947-5-3
Compliance with the Directives (Y/N) Yes
Number of actuating directions1
Active principleelectromechanical
Duty cycle EDMagnet 100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Housing coatingNone
Weight523
Guard locking monitored (Y/N)Yes
Actuator monitored (Y/N)No
Response time< 60
Duration of risk< 120
Time to readiness< 4000
 
Mechanical data
 
Design of electrical connectionconnector plug M12, 4-pole
Mechanical life> 1.000.000 operations
restistance to shock30 g / 11 ms
Resistance to vibration10 HZ … 150 HZ, Amplitude 0,35 mm
Latching force30
Clamping force F2000 N
Tightening torque for cover srews0,7 … 1
Max. Actuating speed≤ 2
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+60
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30 … 95
- non-condensing
Protection classIP67 to IEC/EN 60529
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Rated insulation voltage Ui32 VDC
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Power to unlockNo
Power to lockYes
 
Electrical data - AS interface
 
AS-i Supply voltage26.5 … 31.6 VDC, Protection against polarity reversal
AS-i operating current≤ 100
AS-i Device insulationinternally short-circuit proof
AS-i Specification
- versionV 2.1
- ProfileS-7.B.F.E
- IO-Code0x7
- ID-Code0xB
- ID-Code10xF
- ID-Code20xE
AS-i Inputs
- Channel 1Data bits DI 0/DI 1= dynamic code transmission
- Channel 2Data bits DI 2/DI 3= dynamic code transmission
AS-i Outputs
- DO 0Solenoid control
- DO 1not used
- DO 2not used
- DO 3not used
AS-i Parameter bits
- P0Safety guard and actuator detected
- P1Solenoid interlock locked
- P2magnet voltage in tolerance range
- P3Error
AS-i input module address0
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device
 
Electrical data - Auxiliary voltage (Aux)
 
Supply voltage UB24 VDC (−15 % / +10 %) stabilised PELV
Operating current≤ 500
Device insulation≤ 4 A (if used in accordance with UL 508)
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
AS-i LED switching conditions display
(1) green/red LED (AS-i duo LED)Supply voltage / Communication error / slave address = 0
(2) red LEDdevice error
(3) yellow LEDDevice status
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Miscellaneous data
 
Applications sliding safety guard,
removable guard,
hinged safety guard
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor244
- Length of sensor50
 
Pin assignment
 
1AS-i +
2Aux − (P)
3AS-i −
4Aux + (P)
 
notice
 
Interlocks with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened.
 
Included in delivery
 
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 16.02.2019 - 04:07:52h Kasbase 3.3.0.F.64I