Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Two-hand control panels and Safety mats
• 3 safety contacts, STOP 0
• 1 Signalling output

 
Preferred typ
 
Ordering details
 
Product type descriptionSRB301HC/R-230V
Article number101190596
EAN Code4250116202324
Replaced article number 101193477
eCl@ss27-37-19-01
 
Approval
 
Approval TÜV
USA/CAN
EAC
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, EN 60947-5-1
PLup e (STOP 0)
Control categoryup 4 (STOP 0)
DC99% (STOP 0)
CCF> 65 points
PFH value≤ 2,0 x 10-8/h (STOP 0)
SILup 3 (STOP 0)
Mission time20 Years
- noticeThe PFH value is applicable for the combinations listed in the table for contact load (K) (current through enabling paths) and switching cycle number (n-op/y).
In case of 365 operating days per year and a 24-hour operation, this results in the specified switching cycle times (t-cycle) for the relay contacts.
Diverging applications on request.
 
Global Properties
 
Permanent lightSRB301HC/R
StandardsIEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-78
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, ventilated
- Material of the contactsAgSn0, self-cleaning, positive action
Weight360
Start conditionsStart button (monitored)
Start input (Y/N)Yes
Feedback circuit (Y/N)Yes
Start-up test (Y/N)No
Automatic reset function (Y/N)No
Reset with edge detection (Y/N)Yes
Pull-in delay
- ON delay with reset buttontyp. 50 ms
Drop-out delay
- Drop-out delay in case of power failuretyp. 100 ms
- Drop-out delay in case of emergency stop≤ 20 ms
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Min. Cable section0,25
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)Yes
Mechanical life10.000.000 operations
Electrical lifetimeDerating curve available on request
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+60 °C
Storage and transport temperature
- Min. Storage and transport temperature−40 °C
- Max. Storage and transport temperature+85 °C
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4 kV
- Overvoltage categoryII To VDE 0110
- Degree of pollution2 To VDE 0110
 
Electromagnetic compatibility (EMC)
 
EMC ratingconforming to EMC Directive
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls-
- Max. rated DC voltage for controls-
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz48
- Max. rated AC voltage for controls, 50 Hz240
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz48
- Max. rated AC voltage for controls, 60 Hz240
Contact resistancemax. 100 mΩ
Power consumption1.6 W; 4.2 VA
Type of actuationAC
Rated operating voltage Ue48 … 240 VAC
Frequency range50 / 60 HZ
Electronic protection (Y/N)Yes
Fuse rating for the operating voltageInternal electronic trip,
tripping current F1: > 0,5 A;
primary side: Safety fuse T1A
Current and tension on control circuits
- S13 ... S1424 VDC, Test current: 20 mA
- S23 ... S2424 VDC, Test current: 20 mA
- S13 ... x224 VDC, Test current: 10 mA
Bridging in case of voltage dropsapprox. 100 ms
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)Yes
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)Yes
Number of shutters0 piece
Number of openers2 piece
Cable length1500 m with 1.5 mm²;
2500 m with 2.5 mm²
Conduction resistancemax. 40 Ω
 
Outputs
 
Stop category 10
Stop category0
Stop category 03
Number of safety contacts3 piece
Number of auxiliary contacts1 piece
Number of signalling outputs0 piece
Switching capacity
- Switching capacity of the safety contactsmax. 250 VAC, 8 A ohmic (inductive in case of appropriate protective wiring)
min. 10 V / 10 mA
- Switching capacity of the auxiliary contacts24 VDC, 2 A
Fuse rating
- Protection of the safety contacts8 A slow blow, 10 A quick-blow
- Fuse rating for the auxiliary contacts2 A slow blow, 2.5 A quick-blow
Utilisation category To EN 60947-5-1AC-15: 230 V / 6 A
DC-13: 24 V / 6 A
Note on the utilisation categoryResidual current at ambient temperature up to: - 45°C = 24 A; - 55°C = 18 A; - 60°C = 12 A
Number of undelayed semi-conductor outputs with signaling function0 piece
Number of undelayed outputs with signaling function (with contact)1 piece
Number of delayed semi-conductor outputs with signaling function.0 piece
Number of delayed outputs with signalling function (with contact).0 piece
Number of secure undelayed semi-conductor outputs with signaling function0 piece
Number of secure, undelayed outputs with signaling function, with contact.3 piece
Number of secure, delayed semi-conductor outputs with signaling function0 piece
Number of secure, delayed outputs with signaling function (with contact).0 piece
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s4
LED switching conditions display
- The integrated LEDs indicate the following operating states.
- Position relay K1
- Position relay K2
- Supply voltage UB
 
Miscellaneous data
 
Applications Emergency-Stop button
Guard system
Two-hand control panels
Safety mats
Pull-wire emergency stop switches
 
Dimensions
 
Dimensions
- Width45 mm
- Height100 mm
- Depth121 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
2 channel control shown for a guard-door monitor with two contacts, of which at least one contact has positive break, with external reset button (R).
Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts.
(H2) = Feedback circuit
The control recognises cross-short, cable break and earth leakages in the monitoring circuit.
The wiring diagram is shown with guard doors closed and in de-energised condition.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.