Ordering details |
|
Product type description | AZM 161CC-12/12RKTD-110/230 |
Article number | 101187922 |
EAN Code | 4030661357225 |
eCl@ss | 27-27-26-03 |
|
Approval |
|
Approval | BG
USA/CAN
CCC
EAC |
|
Classification |
|
Standards | EN ISO 13849-1 |
B10d Normally-closed contact (NC) | 2.000.000 |
Mission time | 20 Years |
notice |  |
|
Global Properties |
|
Permanent light | AZM 161 |
Standards | EN 60947-5-1, BG-GS-ET-19 |
Compliance with the Directives (Y/N)  | Yes |
Number of actuating directions | 3 |
Active principle | electromechanical |
Duty cycle ED | Magnet 100 % |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
- Material of the contacts | Silver |
Housing coating | None |
Weight | 500 |
|
Mechanical data |
|
Actuating play in direction of actuation | 5.5 mm |
Design of electrical connection | Cage clamps |
Cable section |
- Min. Cable section | 1 x 0,25 |
- Max. Cable section | 1 x 1.5 |
Mechanical life | > 1.000.000 operations |
notice | All indications about the cable section are including the conductor ferrules. |
Emergency unlocking device (Y/N) | Yes |
Manual release (Y/N) | No |
Emergency release (Y/N) | No |
Latching force | 30 |
Positive break force | 20 |
positive break travel | 10 |
Clamping force F | 2000 N |
Max. Actuating speed | 2 m/s |
Actuating frequency | max. 1000 / h |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 °C |
- Max. environmental temperature | +60 °C |
Protection class | IP67 to IEC/EN 60529 |
|
Electrical data |
|
Design of control element | Normally open contact (NO), Opener (NC) |
Switching principle | Creep circuit element |
Number of auxiliary contacts | 2 |
Number of safety contacts | 4 |
Power to unlock | Yes |
Power to lock | No |
Rated control voltage Us | 110 / 230 VAC |
Power consumption | max. 10 W |
Power consumption | max. 10 W |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Thermal test current Ithe | 6 A |
Utilisation category | AC-15: 230 V / 4 A, DC-13: 24 V / 2,5 A |
Required rated short-circuit current | 1000 A |
Max. fuse rating | 6 A gG D-fuse To DIN EN 60269-1 |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Miscellaneous data |
|
Applications | sliding safety guard,
removable guard,
hinged safety guard |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 130 mm |
- Height of sensor | 90 mm |
- Length of sensor | 30 mm |
|
notice |
|
Emergency exit |
• The emergency exit is used where an intervention in an already locked hazardous area is required |
• Emergency exit by pressing the red push button |
• Resetting by pulling on the latched button |
• Top-side (ordering suffix -TD) or rear-side (ordering suffix -TU) mounting possible |
• A combination of manual release and emergency exit in different mounting directions in only possible for the following variants: -ED/-TU and -TD/-EU |
|
Diagram |
|

Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact |
|
Switch travel diagram |
|

Notes Switch travel diagram
Contact closed
Contact open
Setting range
Break point
Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
|
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
19.02.2019 -
00:07:14h Kasbase 3.3.0.F.64I |