• Safety relay module for double reset
• Suitable for signal processing of potential-free outputs, e.g. command devices
• 1 safety contact, STOP 0

 
 
Ordering details
 
Product type descriptionSRB100DR
Article number101186279
EAN Code4250116202218
eCl@ss27-37-19-01
 
Approval
 
Approval USA/CAN
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, EN 60947-5-1
PFH value≤ 2,0 x 10-8/h (STOP 0)
Mission time20 Years
- noticeThe PFH value is applicable for the combinations listed in the table for contact load (K) (current through enabling paths) and switching cycle number (n-op/y).
In case of 365 operating days per year and a 24-hour operation, this results in the specified switching cycle times (t-cycle) for the relay contacts.
Diverging applications on request.
 
Global Properties
 
Permanent lightSRB100DR
StandardsIEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-78
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, ventilated
- Material of the contactsAg-Ni, self-cleaning, positive action
Weight250
Start conditionsStart button (monitored)
Start input (Y/N)Yes
Feedback circuit (Y/N)No
Start-up test (Y/N)No
Reset after disconnection of supply voltage (Y/N)Yes
Automatic reset function (Y/N)No
Reset with edge detection (Y/N)No
Pull-in delay
- ON delay with reset button50 ms
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Min. Cable section0,25
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)No
Mechanical life10.000.000 operations
Electrical lifetimeDerating curve available on request
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm, ± 15 %
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+60 °C
Storage and transport temperature
- Min. Storage and transport temperature−40 °C
- Max. Storage and transport temperature+85 °C
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4 kV
- Overvoltage categoryIII To VDE 0110
- Degree of pollution2 To IEC/EN 60664-1
 
Electromagnetic compatibility (EMC)
 
EMC ratingconforming to EMC Directive
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls20.4
- Max. rated DC voltage for controls28.8
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz20.4
- Max. rated AC voltage for controls, 50 Hz26.4
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz20.4
- Max. rated AC voltage for controls, 60 Hz26.4
Contact resistancemax. 100 mΩ
Power consumptionmax. 3.2 W; 6.0 VA
Type of actuationAC/DC
Rated operating voltage Ue24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
Frequency range50 / 60 HZ
Electronic protection (Y/N)Yes
Fuse rating for the operating voltageInternal electronic trip, tripping current > 0,5 A,
Reset after approximately 1 second/s
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)No
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)Yes
Number of shutters0 piece
Number of openers2 piece
Cable length1-channel without cross-wire detection: 1500 m with 1.5 mm²;
2 channel without Short-circuit recognition: 2500 m with 2.5 mm²
Conduction resistancemax. 40 Ω
 
Outputs
 
Number of safety contacts1 piece
Number of auxiliary contacts0 piece
Number of signalling outputs0 piece
Switching capacity
- Switching capacity of the safety contactsmax. 250 V, 8 A ohmic (inductive in case of appropriate protective wiring)
Fuse rating
- Protection of the safety contacts8 A gG D-fuse
Utilisation category To EN 60947-5-1AC-15: 230 V / 8 A
DC-13: 24 V / 8 A
Number of undelayed semi-conductor outputs with signaling function0 piece
Number of undelayed outputs with signaling function (with contact)0 piece
Number of delayed semi-conductor outputs with signaling function.0 piece
Number of delayed outputs with signalling function (with contact).0 piece
Number of secure undelayed semi-conductor outputs with signaling function0 piece
Number of secure, undelayed outputs with signaling function, with contact.1 piece
Number of secure, delayed semi-conductor outputs with signaling function0 piece
Number of secure, delayed outputs with signaling function (with contact).0 piece
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s4
LED switching conditions display
- The integrated LEDs indicate the following operating states.
- Position relay K2
- Position relay K1
- Position relay K3
- Supply voltage
 
Miscellaneous data
 
Applications Safety relay module for double reset
 
Dimensions
 
Dimensions
- Width22.5 mm
- Height100 mm
- Depth121 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
Start configuration: 2 time-dependent reset/on switches 1st and 2nd monitoring time between the 1st and 2nd reset button from 3 … 30 seconds adjustable through DIP switches
The monitoring time is set through DIP switches located below the cover of the enclosure front. (Factory setting: 3 seconds)
Actuator configuration: 1-channel control (output impulse approx. 200 ms) of the reset input of a downstream safety relay module
(H2) = Feedback circuit
Edge detection: After the device is reset, the trailing edge is evaluated, so that errors, e.g. welded contacts or manipulations cannot lead to dangerous situations.
The wiring diagram is shown with guard doors closed and in de-energised condition.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 25.04.2019 - 15:55:04h Kasbase 3.3.0.F.64I